Key result
Temporary epicardial pacing wire removal may cause severe bleeding via SVG laceration.
Why the study?
Complications related to temporary epicardial pacing wire removal are unusual but can be serious and catastrophic, warranting further attention.
Case Report (n=1)
Answers are grounded in this paper and cite their sources.
Highlights a rare but potentially catastrophic complication of saphenous vein graft laceration during the removal of temporary epicardial pacing wires.
The safety and efficacy of temporary pericardial pacing wires have been accepted and their use is common after cardiac operations. Complications related to pacing wire removal are unusual but it can be serious and even catastrophic. We report an unusual case of bleeding due the laceration and rent created in the saphenous vein graft wall by the metallic tip of the pacing wire at the time of pacing wire removal.
No takes yet. Share an insight, caveat, or question.
Mishra et al. (2010) conducted a case report in Complication after cardiac surgery (n=1). Temporary epicardial pacing wire removal was evaluated on Bleeding due to laceration of saphenous vein graft. Removal of temporary epicardial pacing wires can cause serious complications, such as bleeding due to laceration of a saphenous vein graft by the metallic tip of the wire.
Synapse has enriched 10 related papers. Consider them for comparative context: