Key result
Unattended automated office BP yields ~4 mm Hg lower systolic readings than conventional office BP.
Why the study?
The difference between unattended automated office blood pressure and conventional office blood pressure under the environment of a health checkup remains unclear.
Does unattended automated office blood pressure (AOBP) measurement differ from conventional office blood pressure (CBP) measurement in a health checkup environment among the general population?
Cross-Sectional (n=491)
Does unattended automated office blood pressure (AOBP) measurement differ from conventional office blood pressure (CBP) measurement in a health checkup environment among the general population?
In a health checkup environment, AOBP yields slightly lower systolic and diastolic readings than CBP, suggesting their combined use may improve detection of white coat and masked hypertension effects.
Answers are grounded in this paper and cite their sources.
AOBP may yield modestly lower readings than CBP in checkups; hypothesis-generating for combined use to refine white-coat and masked hypertension detection.
Unattended automated office blood pressure (AOBP) measurement has been endorsed as the preferred in-office measurement modality in recent Canadian and American clinical practice guidelines. However, the difference between AOBP and conventional office blood pressure (CBP) under the environment of a health checkup remains unclear. We aimed to identify the clinical significance of AOBP as compared to CBP under the environment of a health checkup. There were 491 participants (333 females, mean age of 62.5 years) who were at least 20 years old, including 179 participants who were previously diagnosed with hypertension. Mean AOBPs were 131.8 ± 20.9/76.6 ± 11.7 mm Hg, and CBPs were 135.6 ± 21.6/77.3 ± 11.5 mm Hg. There was a difference of 3.9 mm Hg in systolic blood pressure (SBP) and 0.8 mm Hg in diastolic BP between AOBP and CBP. In all participants, SBP and pulse pressure, as well as the white coat effect (WCE), increased with age. The cutoff value used was 140/90 mm Hg for CBP and 135/85 mm Hg for AOBP, and the prevalence of WCE and masked hypertension effect (MHE) was 12.4% and 14.1%, respectively. Even in a health checkup environment of the general population, there was a difference between the AOBP and CBP, and the WCE was observed more strongly in the elderly with a history of hypertension, suggesting that a combination of AOBP with CBP may be useful in detecting WCE and MHE in all clinical scenarios including health checkups, and help solve the "hypertension paradox" not only in Japan but in all over the world.
No takes yet. Share an insight, caveat, or question.
Sakuma et al. (2020) conducted a cross-sectional in General population (n=491). Unattended automated office blood pressure (AOBP) vs. Conventional office blood pressure (CBP) was evaluated on Systolic blood pressure (MD 3.9). Unattended automated office blood pressure yielded systolic readings 3.9 mm Hg lower and diastolic readings 0.8 mm Hg lower than conventional office blood pressure during health checkups.