Key result
Threshold-based 3D segmentation correlates strongly with 2D methods for measuring epicardial fat volume.
Why the study?
The usefulness of threshold-based 3-dimensional segmentation compared with the traditional 2-dimensional short axis-based method for measuring epicardial fat volume was assessed.
Does threshold-based 3D segmentation correlate with the traditional 2D short axis-based method for measuring epicardial fat volume in patients undergoing coronary CT angiography?
Cross-Sectional (n=100)
Does threshold-based 3D segmentation correlate with the traditional 2D short axis-based method for measuring epicardial fat volume in patients undergoing coronary CT angiography?
Threshold-based 3D segmentation is a useful tool for measuring epicardial fat volume, correlating strongly with the traditional 2D method and distinguishing patients with CAD.
Answers are grounded in this paper and cite their sources.
Supports 3D segmentation as a feasible alternative for epicardial fat quantification; leaves open whether it enhances CAD prediction beyond 2D measures.
BACKGROUND AND OBJECTIVES: We aimed to assess the usefulness of a threshold-based, 3-dimensional (3D) segmentation in comparison with the traditional 2-dimensional (2D) short axis-based method for measurement of epicardial fat volume with 64-slice multidetector computed tomography (MDCT). SUBJECTS AND METHODS: One hundred patients (52 males; mean age, 58.36+/-11.0 years) who underwent coronary CT angiography were enrolled in this study. The epicardial fat volume was measured using the two methods. The existing method was the 2D short axis-based method and the new method was the threshold-based 3D segmentation. Pearson's correlation was used to compare the two measurement methods. We also assessed the relationship between the epicardial fat volume and coronary artery disease (CAD). RESULTS: There were a strong correlation between the epicardial fat volumes determined using the two methods (r=0.956, p<0.001). The mean overestimation of epicardial fat volume by the threshold-based 3D method was 59.89+/-12.00% compared to the 2D short-axis based method. Using the 3D method, the epicardial fat volume was significantly higher in the CAD group than in the controls (165.07+/-48.22 cm(3) vs. 108.39+/-48.03 cm(3), p<0.001). CONCLUSION: Threshold-based 3D segmentation is another easy and useful tool for measuring the epicardial fat volume.
No takes yet. Share an insight, caveat, or question.
Park et al. (2010) conducted a cross-sectional in Coronary artery disease (n=100). Threshold-based 3-dimensional (3D) segmentation vs. 2-dimensional (2D) short axis-based method was evaluated on Correlation of epicardial fat volume measurements between 3D and 2D methods (r=0.956, p=<0.001). Threshold-based 3D segmentation showed a strong correlation with the 2D short axis-based method for measuring epicardial fat volume.
Synapse has enriched 10 related papers. Consider them for comparative context: