Key result
Intraoperative ATP during ICD implantation does not increase myocardial microdamage versus no pacing.
Why the study?
It is unknown whether antitachycardia pacing (ATP) causes myocardial microdamage in ICD recipients, unlike ICD shocks which do cause damage.
Does intraoperative antitachycardia pacing increase myocardial microdamage (measured by hsTnT release) in ICD recipients?
RCT (n=150)
Open-label
1:1 basis in variable randomization blocks stratified by centre and by CRT versus non-CRT ICD systems
Yes
Does intraoperative antitachycardia pacing increase myocardial microdamage (measured by hsTnT release) in ICD recipients?
Intraoperative antitachycardia pacing does not cause significant myocardial microdamage as measured by hsTnT release, supporting its safety for terminating ventricular tachycardia.
Answers are grounded in this paper and cite their sources.
Supports safe use of intraoperative antitachycardia pacing in ICD implantation; confirms lack of relevant myocardial microdamage in this RCT.
Therapy of choice for the primary and secondary prevention of sudden cardiac death is the implantation of an implantable cardioverter defibrillator (ICD). Whereas appropriate and inappropriate ICD shocks lead to myocardial microdamage, this is not known for antitachycardia pacing (ATP). In total, 150 ICD recipients (66 ± 12 years, 81.3% male, 93.3% primary prevention, 30.0% resynchronization therapy) were randomly assigned to an ICD implantation with or without intraoperative ATP. In the group with ATP, the pacing maneuver was performed twice, each time applying 8 impulses à 6 Volt x 1.0 milliseconds to the myocardium. High sensitive Troponin T (hsTnT) levels were determined prior to the implantation and thereafter. There was no significant difference in the release of hsTnT between the two randomization groups (delta TnT without ATP in median 0.010 ng/ml [min. -0.016 ng/ml-max. 0.075 ng/ml] vs. with ATP in median 0.013 ng/ml [min. -0.005-0.287 ng/ml], p = 0.323). Setting a hsTnT cutoff of 0.059 ng/dl as a regularly augmented postoperative hsTnT level, no relevant difference between the two groups regarding the postoperative hsTnT levels above this cutoff could be identified (without ATP n = 10 [14.7%] vs. with ATP n = 16 [21.9%], p = 0.287). There was no significant difference in the release of high sensitive Troponin between patients without intraoperative ATP compared to those with intraoperative ATP. Hence, antitachycardia pacing does not seem to cause significant myocardial microdamage. This may further support its use as a painless and efficient method to terminate ventricular tachycardia in high-risk patients.
No takes yet. Share an insight, caveat, or question.
Semmler et al. (2020) conducted an RCT in Patients scheduled for ICD implantation for primary or secondary prevention of sudden cardiac death and/or cardiac resynchronization therapy (n=150). Intraoperative antitachycardia pacing (ATP) vs. ICD implantation without intraoperative ATP was evaluated on Proportion of patients with relevant myocardial microdamage (postoperative hsTnT > 0.059 ng/ml) (p=0.287). Intraoperative antitachycardia pacing during ICD implantation did not increase the proportion of patients with relevant myocardial microdamage compared to implantation without pacing.
Synapse has enriched 10 related papers. Consider them for comparative context: