Why the study?
In MADIT-RIT, high-rate cutoff and delayed therapy reduced inappropriate ICD interventions compared with conventional programming, but appropriate yet unnecessary therapies were not evaluated.
Does delayed ICD therapy programming reduce unnecessary antitachycardia pacing (ATP) interventions for fast ventricular arrhythmias in primary prevention ICD recipients?
Does delayed ICD therapy programming reduce unnecessary antitachycardia pacing (ATP) interventions for fast ventricular arrhythmias in primary prevention ICD recipients?
Delayed ICD therapy programming significantly reduces unnecessary antitachycardia pacing interventions for fast ventricular arrhythmias without increasing the need for shock therapies.
May not support early ATP programming in primary prevention ICDs; leaves open optimal timing for fast ventricular arrhythmias.
BACKGROUND: In Multicenter Automatic Defibrillator Implantation Trial - Reduce Inappropriate Therapy (MADIT-RIT), high-rate cutoff (arm B) and delayed therapy (arm C) reduced the risk of inappropriate implantable cardioverter-defibrillator (ICD) interventions when compared with conventional programming (arm A); however, appropriate but unnecessary therapies were not evaluated. OBJECTIVE: The purpose of this study was to assess the value of antitachycardia pacing (ATP) for fast ventricular arrhythmias (VAs) ≥ 200 beats/min in patients with primary prevention ICD. METHODS: We compared ATP only, ATP and shock, and shock only rates in patients in MADIT-RIT treated for VAs ≥ 200 beats/min. The only difference between these randomized groups was the time delay between ventricular tachycardia detection and therapy (3.4 seconds vs 4.9 seconds vs 14.4 seconds). RESULTS: In arm A, 11.5% patients had events, the initial therapy was ATP in 10.5% and shock in 1%, and the final therapy was ATP in 8% and shock in 3.5%. In arm B, 6.6% had events, 4.2% were initially treated with ATP and 2.4% with shock, and the final therapy was ATP in 2.8% and shock in 3.8%. In arm C, 4.7% had events, 2.5% were initially treated with ATP and 2.3% with shock, and the final therapy was ATP in 1.4% and shock in 3.3%. The final shock rate was similar in arm A vs arm B (3.5% vs 3.8%; P = .800) and in arm A vs arm C (3.5% vs 3.3%; P = .855) despite the marked discrepancy in initial ATP therapy utilization. CONCLUSION: In MADIT-RIT, there was a significant reduction in ATP interventions with therapy delays due to spontaneous termination, with no difference in shock therapies, suggesting that earlier interventions for VAs ≥ 200 beats/min are likely unnecessary, leading to an overestimation of the value of ATP in primary prevention ICD recipients.
No takes yet. Share an insight, caveat, or question.
Schuger et al. (2020) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: