Key result
CRT response is linked to ~53% lower risk of ventricular arrhythmia vs non-response.
Why the study?
The impact of cardiac resynchronization therapy super-response on ventricular arrhythmia risk remains unclear.
Does CRT super-response or response reduce the risk of ventricular arrhythmia and all-cause mortality compared to non-response in patients receiving cardiac resynchronization therapy?
Meta-Analysis (n=7,605)
Does CRT super-response or response reduce the risk of ventricular arrhythmia and all-cause mortality compared to non-response in patients receiving cardiac resynchronization therapy?
CRT super-responders have a very low absolute risk of ventricular arrhythmia and all-cause mortality, whereas CRT responders retain a non-trivial residual risk, suggesting continued benefit of defibrillators in the latter group.
Answers are grounded in this paper and cite their sources.
May aid ventricular arrhythmia risk stratification in CRT patients; hypothesis-generating pending prospective validation.
AIMS: Response to cardiac resynchronization therapy (CRT) is associated with improved survival, and reduction in heart failure hospitalization, and ventricular arrhythmia (VA) risk. However, the impact of CRT super-response [CRT-SR, increase in left ventricular ejection fraction (LVEF) to ≥ 50%] on VA remains unclear. METHODS AND RESULTS: We undertook a meta-analysis aimed at determining the impact of CRT response and CRT-SR on risk of VA and all-cause mortality. Systematic search of PubMed, EMBASE, and Cochrane databases, identifying all relevant English articles published until 31 December 2019. A total of 34 studies (7605 patients for VA and 5874 patients for all-cause mortality) were retained for the meta-analysis. The pooled cumulative incidence of appropriate implantable cardioverter-defibrillator therapy for VA was significantly lower at 13.0% (4.5% per annum) in CRT-responders, vs. 29.0% (annualized rate of 10.0%) in CRT non-responders, relative risk (RR) 0.47 [95% confidence interval (CI) 0.39-0.56, P < 0.0001]; all-cause mortality 3.5% vs. 9.1% per annum, RR of 0.38 (95% CI 0.30-0.49, P < 0.0001). The pooled incidence of VA was significantly lower in CRT-SR compared with CRT non-super-responders (non-responders + responders) at 0.9% vs. 3.8% per annum, respectively, RR 0.22 (95% CI 0.12-0.40, P < 0.0001); as well as all-cause mortality at 2.0% vs. 4.3%, respectively, RR 0.47 (95% CI 0.33-0.66, P < 0.0001). CONCLUSIONS: Cardiac resynchronization therapy super-responders have low absolute risk of VA and all-cause mortality. However, there remains a non-trivial residual absolute risk of these adverse outcomes in CRT responders. These findings suggest that among CRT responders, there may be a continued clinical benefit of defibrillators.
No takes yet. Share an insight, caveat, or question.
Yuyun et al. (2020) conducted a meta-analysis in Heart failure with cardiac resynchronization therapy (n=7,605). Cardiac resynchronization therapy response vs. Cardiac resynchronization therapy non-response was evaluated on Appropriate implantable cardioverter-defibrillator therapy for ventricular arrhythmia (RR 0.47, 95% CI 0.39-0.56, p=< 0.0001). Cardiac resynchronization therapy response was associated with a lower risk of ventricular arrhythmia compared to non-response.
Synapse has enriched 10 related papers. Consider them for comparative context: