Why the study?
Does the extent of CRT response affect the long-term incidence of appropriate ICD therapy in primary prevention patients?
Does the extent of CRT response affect the long-term incidence of appropriate ICD therapy in primary prevention patients?
Super-responders to CRT remain at significant risk for ventricular arrhythmias over the long term and continue to benefit from ICD treatment despite initial improvement.
Answers are grounded in this paper and cite their sources.
Super-responders to CRT remain at substantial long-term risk for appropriate ICD therapy; leaves open whether response extent modifies arrhythmia incidence in primary prevention.
AIMS: Mortality and ventricular arrhythmias are reduced in patients responding to cardiac resynchronization therapy (CRT). This response is accompanied by improvement in LVEF, and some patients even outgrow original eligibility criteria for implantable cardioverter-defibrillator (ICD) implantation. It is however unclear if these patients still benefit from ICD treatment. The current study aimed to evaluate if the incidence of ICD therapy is related to the extent of CRT response. METHODS AND RESULTS: All patients who underwent primary prevention CRT-defibrillator implantation were included. They were divided into subgroups according to the reduction in LV end-systolic volume (LVESV) 6 months after implantation. Pre-defined subgroups were: negative responders (increased LVESV), non-responders (decreased LVESV 0-14%), responders (decreased LVESV 15-29%), and super-responders (decreased LVESV ≥30%). During a median follow-up of 57 months (25th-75th percentile 39-84), 512 patients were studied [101 (20%) negative responders, 101 (20%) non-responders, 149 (29%) responders, and 161 (31%) super-responders]. In the first year of follow-up super-responders received significantly less appropriate ICD therapy (3% vs. 12%; P < 0.001). The 5-year cumulative incidence of appropriate ICD therapy was 31% [95% confidence interval (CI) 19-43] in negative responders, 39% (95% CI 25-53) in non-responders, 34% (95% CI 25-43) in responders, and 27% (95% CI 18-35) in super-responders, respectively (p = 0.13). CONCLUSIONS: The extent of CRT response was associated with a parallel reduction of appropriate device therapy during the first year of follow-up. Thereafter, no association was observed. Furthermore, 23% of super-responders were treated for potentially life-threatening arrhythmias and benefit from ICD treatment.
No takes yet. Share an insight, caveat, or question.
Heijden et al. (2014) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: