Key result
CRT-D linked to ~74% fewer inappropriate shocks vs. ICD at 24 months.
Why the study?
The incidence of inappropriate shock therapy in patients with combined CRT-D devices compared with non-CRT ICDs is less well described.
Does CRT-D reduce the incidence of inappropriate shock therapy compared with standard ICDs?
Cohort (n=185)
No
Does CRT-D reduce the incidence of inappropriate shock therapy compared with standard ICDs?
Absolute Event Rate: 5% vs 19%
p-value: p=0.017
CRT-D is associated with a significantly lower incidence of inappropriate shock therapy compared to standard ICDs, potentially due to a reduction in atrial fibrillation burden.
CRT-D was associated with fewer inappropriate shocks than ICD; hypothesis-generating and should not yet change practice.
INTRODUCTION: A significant number of patients experience inappropriate shock therapy (IST) from implantable cardioverter-defibrillators (ICD). An increasing number of patients with advanced heart failure receive combined ICD and cardiac resynchronisation therapy devices (CRT-D). The incidence of IST in this group is less well described. We aimed to assess the incidence and predictors of IST in CRT-D patients. METHODS: A retrospective cohort study of prospectively collected data on patients who received an ICD and CRT-D between October 2007 and January 2009 at our institution were studied. The primary outcome measures were the IST event rate and all-cause mortality. RESULTS: A total of 185 patients with ICD/CRT-D (100/85) were included in the analysis. Eighteen patients experienced 35 episodes of IST during the follow-up (21 ± 13 months). There was a significantly lower IST cumulative event rate in the CRT-D vs. ICD group, 5% (CI: 1-13%) vs. 19% (95% CI: 11-30%) by 24 months, (p = 0.017). The majority of the IST was caused by atrial arrhythmias with atrial fibrillation accounting for 28 episodes of IST in nine patients. Multivariate analysis using Cox hazard model including baseline characteristics and coexisting appropriate shock therapy showed that a history of atrial fibrillation/flutter was the strongest independent predictor of IST with a hazard ratio of 3.53 (p = 0.019). CONCLUSION: Patients with CRT-D had a significantly lower incidence of IST compared with patients receiving an ICD. Given that atrial arrhythmia remained the commonest trigger for IST, our finding lends support to the hypothesis that CRT may reduce atrial fibrillation burden in patients receiving CRT-D.
No takes yet. Share an insight, caveat, or question.
Chen et al. (2013) conducted a cohort in Advanced heart failure requiring ICD or CRT-D (n=185). Combined cardiac resynchronisation therapy defibrillators (CRT-D) vs. Non-CRT defibrillators (ICD) was evaluated on Inappropriate shock therapy (IST) event rate (p=0.017). Patients receiving CRT-D had a significantly lower cumulative event rate of inappropriate shock therapy by 24 months compared to those receiving an ICD (5% vs. 19%, p=0.017).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: