Key result
ICD implantation causes severe tricuspid regurgitation via traumatic septal leaflet perforation.
Why the study?
Tricuspid valve perforation is a rare complication after ICD and pacemaker implantation, with reported cases presenting months to years postimplantation.
Case Report (n=1)
Answers are grounded in this paper and cite their sources.
Tricuspid valve perforation is a rare but severe complication of ICD lead placement that can present acutely within weeks of implantation.
Tricuspid valve (TV) perforation is a rare complication after implantable cardioverter defibrillator (ICD) and permanent pacemaker implantation. In reported cases of lead-related TV perforations, patients' present with symptoms months to years postimplantation. We describe a case where a patient presented with signs of severe TV regurgitation secondary to traumatic perforation of the septal leaflet two weeks after ICD implantation and review of the literature associated with this complication.
No takes yet. Share an insight, caveat, or question.
Wilner et al. (2014) conducted a case report in Tricuspid valve perforation (n=1). Implantable cardioverter defibrillator (ICD) implantation was evaluated on Severe tricuspid valve regurgitation secondary to traumatic perforation. Implantable cardioverter defibrillator implantation resulted in severe tricuspid valve regurgitation secondary to traumatic perforation of the septal leaflet two weeks post-procedure in one patient.
Synapse has enriched 10 related papers. Consider them for comparative context: