Key result
Pulse strength drop ≥40% on percutaneous perfusion monitoring is linked to hemodialysis-induced myocardial stunning.
Why the study?
Accurate detection of systemic circulatory stress causing cardiovascular injury during hemodialysis and enabling timely intervention remains challenging.
Does percutaneous perfusion monitoring predict the development of hemodialysis-induced myocardial stunning in patients undergoing hemodialysis?
Observational (n=8)
Does percutaneous perfusion monitoring predict the development of hemodialysis-induced myocardial stunning in patients undergoing hemodialysis?
Absolute Event Rate: 100% vs 0%
p-value: p=0.005
Percutaneous perfusion monitoring can detect early circulatory stress during hemodialysis, predicting myocardial stunning before it occurs and potentially allowing for preemptive intervention.
May support real-time LS monitoring to detect HD-related CV stress; leaves open utility for preemptive intervention.
INTRODUCTION: The safe delivery of hemodialysis (HD) faces dual challenges; the accurate detection of systemic circulatory stress producing cardiovascular (CV) injury, and the ability to enable effective preemptive intervention for such injury. We performed a pilot study to examine the capability of a new noninvasive, real-time monitoring system to detect the deleterious effects of HD on CV stability. METHODS: Monitoring System, Intelomed, Inc., Warrendale, PA, USA). Longitudinal strain (LS) values for 12 left ventricular segments were generated using speckle-tracking software (EchoPac, GE), to assess the presence of HD-induced regional wall motion abnormalities (RWMA), indicative of myocardial stunning. FINDINGS: A reduction in pulse strength (PS) of ≥40% detected by CVI was associated with the development of RWMA (P = 0.005). This reduction occurred in 6/8 patients, all of whom exhibited myocardial stunning. Two patients had no significant reduction in PS nor evidence of myocardial stunning. In subjects with cardiac stunning, the decrease in PS was evident early during HD, 11.49 ± 10 minutes into HD treatment, prior to the detection of RWMA, which were assessed at peak HD stress, mean 210 ± 16.43 minutes into HD treatment. DISCUSSION: Percutaneous perfusion monitoring, using pulse wave analysis, appears to be useful in identifying circulatory stress during HD and predicting the development of HD-induced myocardial stunning with a lead time long enough to consider timely intervention.
No takes yet. Share an insight, caveat, or question.
Penny et al. (2018) conducted an observational in Hemodialysis-induced cardiovascular injury (n=8). Reduction in pulse strength of ≥40% detected by percutaneous perfusion monitoring vs. No significant reduction in pulse strength was evaluated on Development of regional wall motion abnormalities (RWMA) (p=0.005). A reduction in pulse strength of ≥40% detected by percutaneous perfusion monitoring was significantly associated with the development of hemodialysis-induced myocardial stunning (P=0.005).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: