Key result
Novel balloon-expandable synthetic valve adapts to somatic growth in benchtop and sheep models.
Why the study?
Development of a growth-accommodating prosthetic heart valve has remained elusive, leading to multiple high-risk valve replacement surgeries in children with congenital heart valve disease.
Does a geometrically adaptable biomimetic prosthetic valve accommodate growth and preserve functionality in growing sheep models?
Does a geometrically adaptable biomimetic prosthetic valve accommodate growth and preserve functionality in growing sheep models?
A novel geometrically adaptable prosthetic valve successfully accommodated somatic growth in a sheep model, representing a potential paradigm shift for treating congenital heart valve disease in children.
May enable fewer reoperations in children with valve disease; leaves open translation from sheep models to clinical use.
Congenital heart valve disease has life-threatening consequences that warrant early valve replacement; however, the development of a growth-accommodating prosthetic valve has remained elusive. Thousands of children continue to face multiple high-risk open-heart operations to replace valves that they have outgrown. Here, we demonstrate a biomimetic prosthetic valve that is geometrically adaptable to accommodate somatic growth and structural asymmetries within the heart. Inspired by the human venous valve, whose geometry is optimized to preserve functionality across a wide range of constantly varying volume loads and diameters, our balloon-expandable synthetic bileaflet valve analog exhibits similar adaptability to dimensional and shape changes. Benchtop and acute in vivo experiments validated design functionality, and in vivo survival studies in growing sheep demonstrated that mechanical valve expansion accommodated growth. As illustrated in this work, dynamic size adaptability with preservation of unidirectional flow in prosthetic valves thus offers a paradigm shift in the treatment of heart valve disease.
No takes yet. Share an insight, caveat, or question.
Hofferberth et al. (2020) studied Congenital heart valve disease. Biomimetic prosthetic valve (balloon-expandable synthetic bileaflet valve analog) was evaluated. A biomimetic, balloon-expandable synthetic bileaflet prosthetic valve demonstrated geometric adaptability to accommodate somatic growth in benchtop and in vivo sheep models.