Key result
Transjugular LuX-Valve Plus valve-in-ring replacement with 3D-printing guidance achieves successful symptomatic improvement.
Why the study?
Recurrent tricuspid regurgitation after failed ring annuloplasty is associated with high mortality and unfavorable clinical outcomes, and transcatheter tricuspid valve-in-ring replacement remains challenging.
Does transcatheter tricuspid valve-in-ring replacement using the LuX-Valve Plus system improve symptoms in a patient with severe recurrent tricuspid regurgitation after failed annuloplasty?
Case Report (n=1)
Does transcatheter tricuspid valve-in-ring replacement using the LuX-Valve Plus system improve symptoms in a patient with severe recurrent tricuspid regurgitation after failed annuloplasty?
Answers are grounded in this paper and cite their sources.
Transcatheter tricuspid valve-in-ring replacement using the LuX-Valve Plus system with 3D printing guidance is feasible and improves symptoms in patients with failed annuloplasty rings.
Recurrent tricuspid regurgitation after failed ring annuloplasty is associated with high mortality rates and unfavourable clinical outcomes. Transcatheter tricuspid valve-in-ring (TVIR) replacement offers an alternative to high-risk surgical reoperation, but challenges remain. We present a case of a 67-year-old male who underwent tricuspid annuloplasty 3 years ago and developed severe recurrent tricuspid regurgitation (regurgitation volume = 36 mL) 6 months ago. To avoid a high-risk thoracotomy, we finally performed TVIR replacement using the novel device, LuX-Valve Plus system, via the transjugular approach. Cardiovascular three-dimensional printing technology was utilized to investigate the distinct advantages offered by the new device in this specific intervention, as well as to simulate the procedure. Successful TVIR replacement resulted in significant symptomatic improvement. TVIR replacement with the LuX-Valve Plus system is feasible for failed annuloplasty ring cases. Patient-specific three-dimensional printed models enable personalized procedural planning, enhancing safety and precision.
No takes yet. Share an insight, caveat, or question.
Wang et al. (2023) conducted a case report in Severe recurrent tricuspid regurgitation after failed ring annuloplasty (n=1). Transjugular tricuspid valve-in-ring (TVIR) replacement using the LuX-Valve Plus system with 3D printing guidance was evaluated on Symptomatic improvement. Transjugular tricuspid valve-in-ring replacement using the LuX-Valve Plus system with 3D printing guidance was successfully performed, resulting in significant symptomatic improvement.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: