Key result
True bifurcation lesions show no significant difference in long-term TVF vs. nontrue lesions after imaging-guided stenting.
Why the study?
Limited evidence exists regarding the long-term outcomes of true versus nontrue coronary bifurcation lesions treated with current-generation drug-eluting stents and intravascular imaging guidance.
Does the treatment of true versus nontrue coronary bifurcation lesions with bioresorbable polymer sirolimus-eluting stents under imaging guidance result in different rates of target vessel failure?
Cohort (n=440)
No
Does the treatment of true versus nontrue coronary bifurcation lesions with bioresorbable polymer sirolimus-eluting stents under imaging guidance result in different rates of target vessel failure?
Imaging-guided percutaneous coronary intervention with bioresorbable polymer sirolimus-eluting stents using a predominantly 1-stent strategy yields comparable long-term clinical outcomes for both true and nontrue coronary bifurcation lesions.
Answers are grounded in this paper and cite their sources.
TVF rates similar after adjustment in true versus nontrue CBLs; extends limited observational data but leaves generalizability open.
Limited evidence exists regarding the long-term outcomes of true versus nontrue coronary bifurcation lesions (CBLs) treated with current-generation drug-eluting stents and intravascular imaging guidance. The Sapporo Cardiovascular Clinic (SCVC) registry was a prospective, single-center, all-comers registry enrolling 1,727 consecutive patients treated with bioresorbable polymer sirolimus-eluting stent under complete imaging guidance. From this registry, 440 patients with CBLs (25.5%) were analyzed. Patients were categorized into the true and nontrue CBL groups according to the Medina classification (n = 234 and 206, respectively). The primary end point was the cumulative incidence of target vessel failure (TVF) (a composite of cardiac death, target vessel-related myocardial infarction, and clinically driven target vessel revascularization). The 1-stent strategy was predominantly chosen for the true and nontrue CBL groups (93.9% and 96.2%, respectively). During the median follow-up of 5.4 years, the cumulative incidence of TVF did not differ between true and nontrue CBL groups after adjustment for baseline differences (5-year incidence 22.0% vs 17.7%, adjusted hazard ratio 1.27, 95% confidence interval 0.79 to 2.05, p = 0.32). Although the Medina 0.0.1 lesions were very rare (1.1%), they had the highest rate of TVF among the Medina subtypes. Final kissing balloon inflation technique was associated with a lower incidence of TVF (p = 0.036). In conclusion, imaging-guided percutaneous coronary intervention with bioresorbable polymer sirolimus-eluting stent resulted in comparable long-term clinical outcomes between true and nontrue CBLs, primarily using the 1-stent technique.
No takes yet. Share an insight, caveat, or question.
Matsuna et al. (2024) conducted a cohort in Coronary bifurcation lesions (n=440). True coronary bifurcation lesions vs. Nontrue coronary bifurcation lesions was evaluated on Cumulative incidence of target vessel failure (TVF) (a composite of cardiac death, target vessel-related myocardial infarction, and clinically driven target vessel revascularization) (HR 1.27, 95% CI 0.79-2.05, p=0.32). True coronary bifurcation lesions had a similar long-term incidence of target vessel failure compared to nontrue lesions after imaging-guided stenting.
Synapse has enriched 10 related papers. Consider them for comparative context: