Key result
Single-sample 51Cr-EDTA clearance correlates near-perfectly with standard multi-sample clearance.
Why the study?
A simplified method to determine 51Cr-EDTA clearance from one plasma sample between 180 and 240 minutes after injection was needed.
Does a single plasma sample nomogram accurately estimate 51Cr-EDTA clearance compared to the conventional standard method in patients?
Observational (n=99)
Does a single plasma sample nomogram accurately estimate 51Cr-EDTA clearance compared to the conventional standard method in patients?
A single plasma sample drawn between 180 and 240 minutes after injection can accurately estimate 51Cr-EDTA clearance for values above 30 ml/min.
Answers are grounded in this paper and cite their sources.
May simplify single-sample GFR estimation clinically; leaves open prospective validation in diverse populations before wider adoption.
51Cr-EDTA clearance was measured in 99 consecutive patients. Based on the individual plasma activity at 180, 200, 220, and 240 min after injection (normalized with respect to injected dose/body surface area), a nomogram and a formula were derived for the relation between clearance and the plasma activity in one sample drawn between 180 and 240 min after injection. The nomogram was tested by the activity in 141 plasma nomogram were compared to the corresponding clearance value calculated by a conventional standard method. The correlation coefficient for this comparison was r = 0.982. It is recommended that the nomogram should only be used if clearance values above 30 ml/min are expected.
No takes yet. Share an insight, caveat, or question.
Groth et al. (1981) reported an observational. One plasma sample method (180-240 min) vs. Conventional standard method was evaluated on Correlation of clearance values between the one-sample nomogram and the conventional standard method (r = 0.982). A one-plasma-sample method for determining 51Cr-EDTA clearance drawn between 180 and 240 minutes after injection correlated highly with the conventional standard method.