Fenestra VC micro-CT provides sustained enhancement up to ~620 HU for murine cardiac phenotyping vs. Isovue-370.
Why the study?
Noninvasive imaging methods for in vivo characterization of cardiac structure and function in mice require demonstration using high-resolution micro-CT with integrated motion control.
Does simultaneous cardiac- and respiratory-gated micro-CT with contrast agents provide sufficient image quality for in vivo characterization of cardiac structure and function in mice?
Does simultaneous cardiac- and respiratory-gated micro-CT with contrast agents provide sufficient image quality for in vivo characterization of cardiac structure and function in mice?
Simultaneous cardiac- and respiratory-gated micro-CT with a blood pool contrast agent (Fenestra VC) provides sufficient image quality for noninvasive morphological and functional cardiac phenotyping in mice.
Answers are grounded in this paper and cite their sources.
May support gated micro-CT phenotyping in mice; leaves open validation and clinical translation.
PURPOSE: Demonstrate noninvasive imaging methods for in vivo characterization of cardiac structure and function in mice using a micro-CT system that provides high photon fluence rate and integrated motion control. MATERIALS AND METHODS: Simultaneous cardiac- and respiratory-gated micro-CT was performed in C57BL/6 mice during constant intravenous infusion of a conventional iodinated contrast agent (Isovue-370), and after a single intravenous injection of a blood pool contrast agent (Fenestra VC). Multiple phases of the cardiac cycle were reconstructed with contrast to noise and spatial resolution sufficient for quantitative assessment of cardiac function. RESULTS: Contrast enhancement with Isovue-370 increased over time with a maximum of approximately 500 HU (aorta) and 900 HU (kidney cortex). Fenestra VC provided more constant enhancement over 3 hr, with maximum enhancement of approximately 620 HU (aorta) and approximately 90 HU (kidney cortex). The maximum enhancement difference between blood and myocardium in the heart was approximately 250 HU for Isovue-370 and approximately 500 HU for Fenestra VC. In mice with Fenestra VC, volumetric measurements of the left ventricle were performed and cardiac function was estimated by ejection fraction, stroke volume, and cardiac output. CONCLUSION: Image quality with Fenestra VC was sufficient for morphological and functional studies required for a standardized method of cardiac phenotyping of the mouse.
No takes yet. Share an insight, caveat, or question.
Badea et al. (2005) studied Cardiac structure and function imaging. Fenestra VC vs. Isovue-370 was evaluated on Contrast enhancement and image quality for morphological and functional studies. Micro-CT with Fenestra VC provided constant enhancement over 3 hours (maximum ~620 HU in aorta) and sufficient image quality for standardized cardiac phenotyping in mice compared to Isovue-370.