Key result
Peripheral pulse oximetry correlates moderately with transcutaneous oxygen and detects post-revascularization perfusion gains in ischaemia.
Why the study?
Peripheral skin perfusion assessment methods to guide amputation or bypass surgery site planning in vascular disease patients require evaluation for accuracy and simplicity.
Does peripheral pulse oximetry accurately assess peripheral perfusion compared to transcutaneous oxygen measurements and ankle artery Doppler pressures in patients with limb ischaemia?
Observational (n=52)
Does peripheral pulse oximetry accurately assess peripheral perfusion compared to transcutaneous oxygen measurements and ankle artery Doppler pressures in patients with limb ischaemia?
Pulse oximetry may be a more sensitive, accurate, and simple index of peripheral perfusion than transcutaneous oxygen measurement or ankle artery Doppler pressure in patients with limb ischemia.
Answers are grounded in this paper and cite their sources.
May support pulse oximetry for perfusion assessment in limb ischaemia; hypothesis-generating and requires prospective validation before adoption.
Peripheral skin perfusion reflects the level of vascularity and viability of a limb and may help in planning the site of amputation or bypass surgery in patients with vascular disease. This study used peripheral pulse oximetry in 20 healthy volunteers and in 20 patients with limb ischaemia. Pulse oximetry saturation levels (Psa,O2) were compared with ankle artery Doppler pressures and transcutaneous oxygen measurements (Ptc,O2). Recordings were taken at two standard sites distally and referenced to finger and forearm to calculate an index. A significant correlation was found between Ptc,O2 and Psa,O2 in patients with ischaemia (r = 0.68, P less than 0.01). A further group of 12 patients with acute limb ischaemia was similarly assessed before and after revascularization. After revascularization mean(s.d.) Ptc,O2 increased from 38(13) to 44(1) mmHg (P greater than 0.05) and mean(s.d.) Psa,O2 increased from 86(3) to 90(4) per cent (P less than 0.01). These data suggest that pulse oximetry is a more sensitive index of peripheral perfusion than Ptc,O2 or ankle artery Doppler pressure and that, because of its accuracy and simplicity, it merits further use.
No takes yet. Share an insight, caveat, or question.
A 1991 study conducted an observational in Peripheral arterial occlusive disease (n=52). Peripheral pulse oximetry vs. Transcutaneous oxygen measurements was evaluated on Correlation between transcutaneous oxygen measurements (Ptc,O2) and pulse oximetry saturation levels (Psa,O2) in patients with ischaemia (r = 0.68, p=<0.01). Peripheral pulse oximetry significantly correlated with transcutaneous oxygen measurements in ischaemic patients (r=0.68, P<0.01) and detected perfusion increases after revascularization.