Key result
BEVAR, but not MFM, is linked to reduced aneurysm sac systolic and pulse pressure.
Why the study?
Endovascular techniques such as BEVAR and MFM may be alternatives to open thoracoabdominal repair for TAAA, but differences in aneurysm sac pressure between these methods are unclear.
Does branched endovascular aneurysm repair (BEVAR) reduce aneurysm sac pressure compared to multilayer flow modulator (MFM) implantation in patients with thoracoabdominal aortic aneurysm?
Observational (n=22)
Does branched endovascular aneurysm repair (BEVAR) reduce aneurysm sac pressure compared to multilayer flow modulator (MFM) implantation in patients with thoracoabdominal aortic aneurysm?
BEVAR, but not MFM implantation, is associated with an immediate reduction in systolic and pulse pressure in the aneurysm sac in patients with thoracoabdominal aortic aneurysm.
Open thoracoabdominal repair is the gold standard in the TAAA treatment. However, there are endovascular techniques, that sometimes may be an alternative, such as branched endovascular aneurysm repair (BEVAR) or implantation of the multilayer flow modulator (MFM). In this study, we aimed to assess differences in the aneurysm sac pressure (ASP) between patients undergoing BEVAR and MFM implantation. The study included 22 patients with TAAA (14 patients underwent BEVAR, while eight MFM implantation). The pressure sensor wire was placed inside the aneurysm. A measurement of ASP and aortic pressure (AP) was performed during the procedure. The systolic pressure index (SPI), diastolic pressure index (DPI), and pulse pressure index (PPI) were calculated as a quotient of the ASP and AP values. After the procedure, SPI and PPI were lower in the BEVAR group than in the MFM group. During a procedure, a drop in SPI and PPI was noted in patients undergoing BEVAR, while no changes were revealed in the MFM group. This indicates that BEVAR, but not MFM, is associated with a reduction in systolic and pulse pressure in the aneurysm sac in patients with TAAA.
No takes yet. Share an insight, caveat, or question.
Antkiewicz et al. (2022) conducted an observational in Thoracoabdominal Aortic Aneurysm (n=22). Branched endovascular aneurysm repair (BEVAR) vs. Multilayer flow modulator (MFM) implantation was evaluated on Aneurysm sac pressure (ASP) indices including systolic pressure index (SPI), diastolic pressure index (DPI), and pulse pressure index (PPI). Branched endovascular aneurysm repair (BEVAR), but not multilayer flow modulator implantation, was associated with a reduction in systolic and pulse pressure in the aneurysm sac.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: