Key result
TENS causes delayed biventricular ICD interference at 6 months despite negative initial testing.
Why the study?
The potential for interference between biventricular ICDs and TENS devices and its clinical implications remain unclear despite known electromagnetic interference risks.
Does the simultaneous use of a TENS unit and a biventricular ICD cause device interference?
Case Report (n=1)
Does the simultaneous use of a TENS unit and a biventricular ICD cause device interference?
Patients with a biventricular ICD require careful follow-up for potential interaction with TENS units, even if initial testing is negative, and should be cautioned against their use, especially if pacemaker-dependent.
Answers are grounded in this paper and cite their sources.
Delayed TENS interference with biventricular ICDs may occur late despite negative testing; single case leaves open need for prospective safety data.
Undesirable sensing of external sources of electromagnetic interference by ICDs is well known. A transcutaneous electrical nerve stimulation (TENS) device has been reported to interfere with an ICD resulting in an inappropriate shock and patients with implanted defibrillators or pacemakers have been cautioned about the use of such units to treat chronic pain. We describe a patient regularly using TENS therapy for pain who subsequently received a biventricular ICD for malignant ventricular arrhythmias and medically refractory cardiac failure. He underwent testing for device interaction immediately post-implant. This did not show inappropriate sensing by either ICD or pacemaker component of his heart failure device. However, six months later, the patient complained of dizziness and bradycardia with application of TENS. Further testing did reveal interference with pacemaker function. Thus, even if initial testing is negative and reassuring, patients with a biventricular ICD still require careful follow-up for potential interaction and should be cautioned against the use of TENS, especially if they are pacemaker-dependent.
No takes yet. Share an insight, caveat, or question.
Jason R. Pyatt (2002) conducted a case report in Malignant ventricular arrhythmias, medically refractory cardiac failure, and chronic pain (n=1). Transcutaneous electrical nerve stimulation (TENS) was evaluated on Device interaction / interference with pacemaker function. Application of TENS in 1 patient with a biventricular ICD caused delayed pacemaker interference resulting in dizziness and bradycardia at 6 months, despite negative initial testing.