Pediatric blood analog alters VAD fluid dynamics vs. goat blood, questioning animal models.
Why the study?
The development of pediatric ventricular assist devices is challenged by the use of small-diameter aortic cannulae and the impact of blood viscoelasticity on fluid dynamics, raising questions about the predictive value of animal testing for pediatric patients.
Does the fluid dynamics of a pediatric viscoelastic blood analog differ from a goat viscoelastic blood analog in a PVAD aortic cannula model?
Does the fluid dynamics of a pediatric viscoelastic blood analog differ from a goat viscoelastic blood analog in a PVAD aortic cannula model?
In vitro fluid dynamics differ between pediatric and goat blood analogs in PVAD cannulae, raising questions about the predictive value of animal testing for pediatric patients.
Hematocrit effects on pediatric VAD cannula flow warrant design scrutiny; leaves open in vivo validation before clinical translation.
A challenge to the development of pediatric ventricular assist devices (PVADs) is the use of the aortic cannulae attached to the devices. Cannulae used for pediatric application have small diameters and large pressure drops. Furthermore, during the development of the 12cc Penn State pediatric PVAD, particle image velocimetry (PIV) illustrated that hematocrit levels, through changes in blood viscoelasticity, affected the fluid dynamics. The objective of this study is to compare the fluid dynamics of a pediatric viscoelastic blood analog and a goat viscoelastic blood analog within the PVAD aortic cannula. Two acrylic models were manufactured to model the aortic cannula (6 mm and 8 mm diameters). PIV data was collected to examine the flow at the outlet of the VAD and in the aortic cannula at heart rates of 50 and 75 beats per minute (bpm). Three planes of data were taken, one at the centerline and two 1.5 mm above and below the centerline. Three more planes of data were taken orthogonal to the original planes. While a 75 bpm heart rate was used to represent normal operating conditions, a 50 bpm heart rate represented use of the PVAD during weaning. At 75 bpm, differences were evident between the two different fluids and the two models. Separation zones developed in the plane below the centerline for the higher hematocrit pediatric blood analog. This study raises question to the usefulness of animal testing results in regard to how well they predict the outcome of pediatric patients.
No takes yet. Share an insight, caveat, or question.
Long et al. (2012) studied Pediatric ventricular assist devices (PVADs). Pediatric viscoelastic blood analog vs. Goat viscoelastic blood analog was evaluated on Fluid dynamics and separation zones at heart rates of 50 and 75 bpm. A pediatric viscoelastic blood analog demonstrated different fluid dynamics, including separation zones at 75 bpm, compared to a goat blood analog, questioning the predictive value of animal testing.