Key result
Isolated external suture annuloplasty is linked to a ~52% reduction in type Ic AR grade.
Why the study?
Surgical intervention for moderate or less aortic regurgitation during other cardiovascular surgeries remains controversial, especially for type Ic lesions caused by aortic annular dilatation.
Does isolated external suture annuloplasty improve aortic regurgitation grade and ventriculoaortic junction size in patients with moderate or less type Ic aortic regurgitation undergoing other cardiovascular surgeries?
Observational (n=10)
Does isolated external suture annuloplasty improve aortic regurgitation grade and ventriculoaortic junction size in patients with moderate or less type Ic aortic regurgitation undergoing other cardiovascular surgeries?
Isolated external suture annuloplasty is an effective and durable technique for treating moderate or less type Ic aortic regurgitation during concomitant cardiovascular surgeries without adding clinically relevant procedural time.
Answers are grounded in this paper and cite their sources.
May support adjunctive use during concomitant surgery; leaves open randomized evaluation for isolated type Ic AR.
BACKGROUND Surgical intervention for moderate or less aortic regurgitation (AR) during other cardiovascular surgeries remains controversial. We have applied external suture annuloplasty (ESA) in cases where aortic annular dilatation (type Ic lesion) is the main cause of AR. Here, we investigated the efficacy and durability of ESA in such cases. METHODS From 2018 to 2024, 10 patients with moderate or less type Ic AR underwent isolated ESA during other cardiovascular surgeries. The patients were followed up with annual transthoracic echocardiography. RESULTS The average age was 69 ± 7.4 years. The mean duration of the midterm follow-up was 5.7 ± 2.9 years. The procedural time for ESA alone was 10.3 ± 2.9 min. There were no cases of operative mortality, major morbidity, or reintervention for aortic valve due to progression of AR during the observation period. Preoperative AR grade was 2.9 ± 0.2, which was significantly improved at discharge and midterm follow-up (1.2 ± 0.4, 1.4 ± 0.7, respectively, P < 0.01). The preoperative ventriculoaortic junction size was 26.9 ± 2.8 mm, which was significantly decreased at discharge and remained stable at midterm follow-up (21.8 ± 1.8 mm, 21.3 ± 1.6 mm, respectively, P < 0.01). The transvalvular peak pressure gradient had not increased significantly at midterm follow-up compared to baseline (midterm: 9.42 ± 6.38 mmHg, baseline: 8.40 ± 5.82 mmHg, P = 0.41). CONCLUSIONS Isolated ESA for pure type Ic AR is effective without clinically relevant additional procedural time, and provides excellent midterm repair durability.
No takes yet. Share an insight, caveat, or question.
Maeda et al. (2026) conducted an observational in Moderate or less type Ic aortic regurgitation (n=10). Isolated external suture annuloplasty was evaluated on Aortic regurgitation grade at midterm follow-up (p=<0.01). Isolated external suture annuloplasty for type Ic aortic regurgitation improved AR grade from 2.9 preoperatively to 1.4 at 5.7 years, with no operative mortality.
Synapse has enriched 10 related papers. Consider them for comparative context: