Key result
IFR through 4Fr catheters shows strong agreement with 5Fr measurements, with ~0 mean difference.
Why the study?
Clinical evidence of coronary pressure assessment through a diagnostic catheter is limited, necessitating evaluation of iFR measurement differences between 4Fr and 5Fr catheters.
Observational (n=24)
No
Answers are grounded in this paper and cite their sources.
Background Clinical evidence of coronary pressure assessment through a diagnostic catheter is limited. The aim of this study was to assess the difference, safety, and rate of successful measurement of Instantaneous Wave-free Ratio (iFR) through 4Fr and 5Fr diagnostic catheters. Methods This single-centre prospective study included 32 lesions among 24 patients exhibiting intermediate coronary stenosis on coronary angiography. iFR measurements were performed through 4Fr and 5Fr diagnostic catheters for each lesion. The primary outcome was the reliability, as assessed by a Bland—Altman plot, for comparison of the mean differences [mean ± 2 Standard Deviations (SDs)], and the agreement on the Kappa coefficient, using a threshold iFR value of 0.89. The secondary outcome was the rate of successful iFR measurement. Safety was assessed by procedural complications and in-hospital Major Adverse Cardiac Events (MACE). Results The mean difference was −0.0003 ± 0.058, according to the Bland–Altman plot. One lesion was out of the range of 2 SDs. There was good agreement (Kappa coefficient = 0.85), and the correlation coefficient between the 4Fr and 5Fr catheters was 0.948 (p < 0.001). The success rate was not significantly different between the 4Fr and 5Fr catheters (90.6% vs. 96.9%, p = 0.09), although the 4Fr catheter had a lower success rate. No procedural complications or in-hospital MACE occurred. Conclusion Our findings suggest that iFR measurements could be safely performed, with similar reliability and success rate, through either the 4Fr or 5Fr diagnostic catheter.
No takes yet. Share an insight, caveat, or question.
Masuda et al. (2020) conducted an observational in Stable angina pectoris with intermediate coronary stenosis (n=24). 4Fr diagnostic catheter vs. 5Fr diagnostic catheter was evaluated on Reliability of iFR values (mean difference assessed by Bland-Altman plot) (MD -0.0003, 95% CI -0.059 to 0.058, p=<0.001). Instantaneous wave-free ratio (iFR) measurements performed through 4Fr and 5Fr diagnostic catheters showed strong correlation and good agreement, with a mean difference of -0.0003.
Synapse has enriched 10 related papers. Consider them for comparative context: