Key result
D-dimer shows ~97% sensitivity for detecting acute aortic dissection.
Why the study?
The diagnostic accuracy of D-dimer testing for detection of acute aortic dissection in the emergency department was uncertain.
Observational (n=99)
No
Answers are grounded in this paper and cite their sources.
D-dimer may aid ruling out acute aortic dissection in suspected cases; hypothesis-generating and requires prospective validation.
OBJECTIVE: To determine the diagnostic accuracy of D-dimer testing for detection of acute aortic dissection. METHODS: This study is a retrospective chart review of patients who had been evaluated with suspicion of acute aortic dissection. All patients' D-dimer levels were determined prior to their further work up in the emergency department. The study was conducted in a tertiary care center between February 2006-August 2008. The D-dimer assay used was the immunoturbidimetric assay, with a normal range up to 0.246 µg/ml. Statistical analysis was accomplished using Chi-square test, Student's t-test and a receiver-operating characteristics (ROC) curve analysis. RESULTS: Ninety-nine patients were included in the study, 30 patients were diagnosed as having acute aortic dissection and 69 patients were evaluated in non-acute aortic dissection group. In comparison of the two groups, positive D-dimer results were found to be significantly higher in acute aortic dissection group than in non-acute aortic dissection group (p=0.001). Sensitivity of the D-dimer test in detection of acute aortic dissection was found as 96.6% and the negative predictive value of the test was 97.3%. Specificity and positive predictive value of the D-dimer test were 52.2% and 46.8%, respectively. The area under the ROC curve yielded an acceptable certainty for excluding acute aortic dissection on base of negative results (AUC: 0.764; CI 95%: 0.674-0.855; p=0.001). CONCLUSION: D-dimer testing is helpful for emergency physicians in detection of patients with suspected acute aortic dissection in the emergency department.
No takes yet. Share an insight, caveat, or question.
Ersel et al. (2010) conducted an observational in Suspected acute aortic dissection (n=99). D-dimer testing vs. Non-acute aortic dissection was evaluated on Diagnostic accuracy for acute aortic dissection (AUC 0.764, 95% CI 0.674-0.855, p=<0.001). D-dimer testing demonstrated a sensitivity of 96.6% and a negative predictive value of 97.3% for detecting acute aortic dissection, with an AUC of 0.764.
Synapse has enriched 10 related papers. Consider them for comparative context: