Key result
Omitting predilatation in TAVI matches standard hemodynamics while reducing rapid pacing runs.
Why the study?
The necessity of balloon predilatation in transcatheter aortic valve implantation (TAVI) was uncertain and not well documented.
RCT (n=60)
Double-blind
double envelope system
No
Answers are grounded in this paper and cite their sources.
Omitting predilatation showed no early hemodynamic differences in TAVI; hypothesis-generating and should not yet change practice.
BACKGROUND: The use of a balloon expandable stent valve includes balloon predilatation of the aortic stenosis before valve deployment. The aim of the study was to see whether or not balloon predilatation is necessary in transcatheter aortic valve replacement (TAVI). METHODS: Sixty consecutive TAVI patients were randomized to the standard procedure or to a protocol where balloon predilatation was omitted. RESULTS: There were no significant differences between the groups regarding early hemodynamic results or complication rates. CONCLUSIONS: TAVI can be performed safely without balloon predilatation and with the same early results as achieved with the standard procedure including balloon predilatation. The reduction in the number of pacing periods required may be beneficial for the patient.
No takes yet. Share an insight, caveat, or question.
Ahn et al. (2016) conducted an RCT in Aortic valve stenosis (n=60). Omission of balloon predilatation during TAVI vs. Standard TAVI with balloon predilatation was evaluated on Hemodynamic non-inferiority (mean gradient in mmHg at 1-month follow-up) (p=ns). Omission of balloon predilatation during TAVI resulted in similar early hemodynamic outcomes and complication rates compared to the standard procedure, while significantly reducing the number of required rapid pacing periods.
Synapse has enriched 10 related papers. Consider them for comparative context: