Key result
CineECG detects acute ischemia with a ~15% increase in ST-segment amplitude during balloon inflation.
Why the study?
CineECG has not been used to visualize ventricular activation patterns during ischemia and its ability to detect changes in ventricular electrical activity during acute ischemia is unknown.
Does CineECG detect changes in ventricular activity during acute ischemia in patients undergoing percutaneous coronary intervention?
Observational (n=94)
Does CineECG detect changes in ventricular activity during acute ischemia in patients undergoing percutaneous coronary intervention?
Absolute Event Rate: 0.045% vs 0.039%
CineECG can detect early changes in ventricular electrical activity during acute ischemia before distinct standard ECG changes become visible.
CineECG may aid early ischemia detection during PCI; extends vector-based ECG analysis but leaves open clinical utility versus standard monitoring.
BACKGROUND: CineECG offers a visual representation of the location and direction of the average ventricular electrical activity throughout a single cardiac cycle, based on the 12‑lead ECG. Currently, CineECG has not been used to visualize ventricular activation patterns during ischemia. PURPOSE: To determine the changes in ventricular activity during acute ischemia with the use of CineECG, and relating this to changes in the ECG. METHODS: Continuous ECG's during percutaneous coronary intervention with prolonged balloon inflation from the STAFF III database were analyzed with CineECG at baseline and every 10 s throughout the first 150 s of balloon inflation. The CineECG direction was determined for the initial QRS-complex, terminal QRS-complex, ST-segment and T-wave. Changes in the CineECG were quantified by calculating the Δangle between the direction at baseline and the direction at every 10 s of inflation. Additionally, the root mean square amplitude (rmsA) of the ST-segment was computed. RESULTS: 94 patients were included. At start inflation, the median Δangle was 14.7° [7.5-33.4], 21.8° [11.4-34.2], 20.6° [8.0-43.9], and 23.5° [11.8-48.0] for the initial QRS-complex, terminal QRS-complex, ST-segment and T-wave, respectively. Meanwhile, the median rmsA increased from 0.039 mV [0.027-0.058] at baseline to 0.045 mV [0.033-0.075] at start of inflation. CONCLUSIONS: CineECG was able to detect immediate changes in ventricular electrical activity during induced ischemia, while changes in the ST-segment of the ECG were still subtle. Therefore, CineECG might support the early detection of acute ischemia, even before distinct ECG changes become visible.
No takes yet. Share an insight, caveat, or question.
Schaaf et al. (2024) conducted an observational in Acute ischemia (n=94). CineECG vs. Baseline (pre-inflation) was evaluated on Root mean square amplitude (rmsA) of the ST-segment. CineECG detected immediate changes in ventricular electrical activity during induced ischemia, with median rmsA increasing from 0.039 mV at baseline to 0.045 mV at start of inflation.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: