Key result
Pre-implantation apicobasal depolarization gradient independently predicts 6-month echocardiographic CRT response.
Why the study?
A proportion of CRT patients with ECG-evidenced electrical dyssynchrony remain non-responders, and visualization of the depolarization sequence could improve CRT response prediction.
Does the CineECG-derived depolarization sequence predict echocardiographic response to cardiac resynchronization therapy in adult heart failure patients?
Cohort (n=121)
Does the CineECG-derived depolarization sequence predict echocardiographic response to cardiac resynchronization therapy in adult heart failure patients?
CineECG-derived spatial depolarization characteristics, specifically the pre-implantation apicobasal gradient, can independently predict echocardiographic response to cardiac resynchronization therapy.
Background Electrical ventricular dyssynchrony is a hallmark of intraventricular conduction disease in heart failure with reduced ejection fraction. Although cardiac resynchronization therapy (CRT) is effective, a proportion of patients with ECG evidenced electrical dyssynchrony remain non-responders. Besides the QRS duration, visualization and quantification of the depolarization sequence could contribute to improving CRT response. Objective The study aimed to evaluate the CineECG-derived mean temporo-spatial isochrone trajectory of depolarization in CRT patients. Methods Among the adult cohort of 121 patients who underwent CRT implantation, there were 93 (33% female) responders and 28 (7% female) non-responders. ECGs recorded before and immediately after CRT implantation were collected and analyzed using the CineECG modality with a generic heart/torso model. The CineECG-derived path directions were computed for the QRS on anteroposterior, interventricular, and apicobasal axes within the cardiac anatomy. Spatial depolarization characteristics were tested for the association with left ventricle reverse-remodeling at six-month follow-up. Results The pre-implantation depolarization sequence was predominantly from the right to the left ventricle, and after the CRT implant, it has been transformed into an apicobasal direction. In multivariate logistic regression, the pre-implant QRS duration, apicobasal depolarization gradient, and CRT-induced QRS shortening independently predicted CRT response. The Akaike information criterion indicated that combining all three yielded the strongest predictive model. Conclusion CineECG-derived depolarization gradients, which reflect ventricular activation sequence, changed significantly after CRT, and the pre-implantation apicobasal gradient independently predicted echocardiographic outcome, with a less pronounced gradient associated with better hemodynamic response.
No takes yet. Share an insight, caveat, or question.
Sedova et al. (2026) conducted a cohort in Heart failure with reduced ejection fraction (n=121). Pre-implantation apicobasal depolarization gradient was evaluated on CRT response (left ventricle reverse-remodeling at six-month follow-up). The pre-implantation apicobasal depolarization gradient independently predicted echocardiographic response at 6 months among 121 CRT patients, where 93 were responders and 28 non-responders.