Key result
Cine nuclear magnetic resonance imaging demonstrated high concordance with biplane left ventricular cineangiography for assessing regional ventricular wall motion, with agreement within one grade in over 92% of evaluated segments.
Why the study?
Previous NMR imaging studies to assess left ventricular function used multiple axial planes that were compromised by partial volume effects and were time consuming to acquire and analyze.
Does cine nuclear magnetic resonance imaging provide a comparable assessment of regional ventricular wall motion compared to biplane left ventricular cineangiography?
Observational (n=55)
Does cine nuclear magnetic resonance imaging provide a comparable assessment of regional ventricular wall motion compared to biplane left ventricular cineangiography?
Cine nuclear magnetic resonance imaging using planes aligned with true cardiac axes provides a highly comparable assessment of regional left ventricular wall motion to biplane cineangiography.
Previous nuclear magnetic resonance (NMR) imaging studies to assess left ventricular function have used multiple axial planes, which are compromised by partial volume effects and are time consuming to acquire and analyze. Accordingly, an imaging approach using cine NMR and planes aligned with the true cardiac axes of the left ventricle was developed in views comparable with left ventricular cineangiography. Cine NMR imaging was used to assess regional wall motion and was validated by comparison with biplane left ventricular cineangiography. Fifty-nine patients underwent cineangiographic and NMR studies within 72 h. A poor quality NMR study precluded analysis in 4. leaving a study group of 55 patients (mean age 58 +/- 12: 17 women). Cine NMR movie loops were acquired in two long-axis planes: 1) right anterior oblique plane, parallel to the septum, and 2) four chamber orthogonal plane, perpendicular to the septum (this view is comparable to the angiographic left anterior oblique view). To assess regional wall motion, the left ventricle in both cine NMR and cineangiographic images was divided into five segments and graded on a five point grading scale from 3 for normal through 0 for akinesia and -1 for dyskinesia. Regional wall thickening was used qualitatively to aid in the analysis of wall motion. For the 275 segments compared in the right anterior oblique view, agreement was within one grade in 263 (95.6%) of 275 segments, whereas absolute agreement was observed in 171 (62%) of 275 segments. In the left anterior oblique view, of 200 segments evaluated, agreement within one grade was achieved in 184 segments (92%) and agreement was complete in 132 (66%).(ABSTRACT TRUNCATED AT 250 WORDS)
No takes yet. Share an insight, caveat, or question.
Lotan et al. (1989) conducted an observational in Assessment of regional ventricular function (n=55). Cine nuclear magnetic resonance (NMR) imaging vs. Biplane left ventricular cineangiography was evaluated on Agreement of regional wall motion grading between cine NMR and cineangiography. Cine nuclear magnetic resonance imaging demonstrated high concordance with biplane left ventricular cineangiography for assessing regional ventricular wall motion, with agreement within one grade in over 92% of evaluated segments.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: