Key result
LV and BiV antitachycardia pacing linked to ~19 percentage point higher VT termination than RV-ATP.
Why the study?
The efficacy and safety of different antitachycardia pacing sites in terminating ventricular tachycardia among heart failure patients with a biventricular implantable cardioverter-defibrillator needed evaluation.
Observational (n=89)
AIMS: We sought to evaluate the efficacy and safety of different antitachycardia pacing (ATP) sites in heart failure (HF) patients with a biventricular implantable cardioverter-defibrillator (ICD). METHODS AND RESULTS: Between January 2003 and December 2008, 89 consecutive patients with biventricular (BiV) ICDs (Medtronic Inc., St Paul, Minnesota, USA) were enrolled. In these patients, stored electrograms of the true spontaneous ventricular tachycardia (VT) episodes with at least one ATP therapy were analysed. Out of the 89 patients, 46 experienced 259 VT episodes. When we considered all VT forms, both left ventricular (LV)-ATP (91%) and BiV-ATP (89%) were significantly better than right ventricular (RV)-ATP (72%) in terminating VTs (P = 0.03 and 0.04, respectively). In the fastVT zone, there was a trend for higher efficacy of BiV-ATP compared with RV-ATP and LV-ATP (75 vs. 60 vs. 60%, P = 0.10). Fast VT acceleration occurred to a similar extent in all ATP groups (20% in RV-ATP vs. 20% in LV-ATP vs. 20% in BiV-ATP, P = NS). In the slow VT zone, RV-ATP was significantly less effective than LV-ATP (74 vs. 100%, P = 0.001) and BiV-ATP (74 vs. 100%, P = 0.014). Incidence of acceleration was lower with LV-ATP and BiV-ATP than RV-ATP (0 vs. 0 vs. 9%, P = 0.03) in the slow VT zone. CONCLUSIONS: In HF patients treated with BiV ICD, overall ATP efficacy is higher when delivered from LV or BiV than from RV. Biventricular-ATP and LV-ATP are also safer than RV-ATP in the slow VT zone.
No takes yet. Share an insight, caveat, or question.
Haghjoo et al. (2011) conducted an observational in Heart failure and ventricular tachycardia in patients with biventricular ICD (n=89). Left ventricular (LV) or biventricular (BiV) antitachycardia pacing (ATP) vs. Right ventricular (RV) antitachycardia pacing (ATP) was evaluated on Termination of spontaneous ventricular tachycardia episodes (p=0.03). Left ventricular-ATP (91%) and biventricular-ATP (89%) were more effective than right ventricular-ATP (72%) in terminating ventricular tachycardia (P=0.03 and P=0.04, respectively).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: