Key result
Hybrid coil and plug closure achieves near-complete occlusion of persistent LAAO peri-device leak.
Why the study?
Left atrial appendage occlusion (LAAO) is an emerging alternative to long-term anticoagulation in patients with atrial fibrillation, but peri-device leaks remain a clinical challenge.
Case Report (n=1)
This case illustrates that a hybrid coil- and plug-based strategy can achieve near-complete occlusion of persistent peri-device leaks following left atrial appendage occlusion, while underscoring the necessity of continued anticoagulation when complete occlusion is not achieved.
Answers are grounded in this paper and cite their sources.
Case supports individualized LAAO sizing in enlarged appendages; leaves open long-term leak management strategies in high-risk AF.
Background Left atrial appendage occlusion (LAAO) is an emerging alternative to long-term anticoagulation in patients with atrial fibrillation, but peri-device leaks remain a clinical challenge. Case summary A 63-year-old man with permanent atrial fibrillation, heart failure, a prior ischemic stroke history was referred for LAAO due to recurrent anticoagulation-related bleeding. Pre-procedural computer tomography (CT) showed a markedly enlarged appendage suitable for a 35 mm WATCHMAN FLX®, which was implanted under intracardiac echocardiography guidance, with subsequent transition to aspirin. Three months later, CT revealed a tilted device with a peri-skirt leak; an ischemic stroke had occurred in the interim, and anticoagulation was resumed. An Amplatzer Vascular Plug II was implanted but follow-up CT demonstrated persistent contrast passage and more but incomplete occlusion. Three months later, the patient experienced a second stroke, and CT confirmed ongoing peri-device flow. A hybrid leak-closure procedure was performed with coils in the appendage and within the device, followed by a 12 mm plug at the leak channel, achieving near-complete occlusion. At 7-month follow-up, the patient remained on rivaroxaban therapy, briefly interrupted due to haematuria associated with nephrolithiasis. Discussion Most cases of peri-device leak after LAAO are related to suboptimal device alignment, incomplete endothelialization, or persistent peri-skirt channels. In our case, device tilt with a peri-skirt tract persisted despite initial plug-based closure. This case provides insight into the potential role of hybrid coil- and plug-based strategies in enhancing occlusion but also highlights that anticoagulation remains necessary when full occlusion is not obtained.
No takes yet. Share an insight, caveat, or question.
Sulaiman et al. (2026) conducted a case report in Persistent peri-device leak following left atrial appendage occlusion in permanent atrial fibrillation (n=1). Hybrid coil- and plug-based leak closure (coils plus a 12 mm plug) was evaluated on Near-complete occlusion of persistent peri-device leak. Hybrid coil- and 12 mm plug-based closure achieved near-complete occlusion of a persistent LAAO peri-device leak in a 63-year-old man, though anticoagulation remained necessary at 7 months.