Key result
Transvenous lead extraction in ARVC achieves 100% complete removal without major procedural complications.
Why the study?
Patients with ARVC frequently require ICD therapy, but predominant right ventricular disease with wall thinning raises concern regarding the safety of transvenous lead extraction.
Is transvenous lead extraction of ICD leads safe and effective in patients with arrhythmogenic right ventricular cardiomyopathy (ARVC)?
Cohort (n=11)
Yes
Is transvenous lead extraction of ICD leads safe and effective in patients with arrhythmogenic right ventricular cardiomyopathy (ARVC)?
This first reported series demonstrates that transvenous ICD lead extraction can be performed safely and with 100% complete removal in ARVC patients at high-volume centers despite right ventricular wall thinning.
Answers are grounded in this paper and cite their sources.
Supports transvenous extraction feasibility in ARVC at experienced centers; leaves open need for larger prospective studies to confirm safety.
BACKGROUND: Arrhythmogenic right ventricular cardiomyopathy (ARVC) is becoming a more commonly diagnosed entity with frequent need for coincident implantable cardioverter defibrillator (ICD) therapy. Given predominant right ventricular disease with thinning of the wall, there is concern regarding the safety of transvenous lead extraction (TLE) in ARVC. METHODS: We performed a retrospective study of consecutive patients with ARVC undergoing TLE of ICD leads at three high-volume centers. Patient and lead characteristics, indications, outcomes, and extraction sheath (ES) use were analyzed. RESULTS: Between 1999 and 2012, more than 2,000 lead extractions were performed at the three centers. Of these, 11 patients underwent 14 extractions meeting inclusion criteria. Mean implant duration was 74.5 months (range 6-140). In 11 patients, a total of 22 leads (16 high-voltage and six pace-sense leads) were extracted in 14 procedures. The cohort was 50% male with a mean age of 45 years (range, 25-56) and mean ejection fraction 55 ± 13%. The majority (64%) of leads were extracted due to lead malfunction, three patients had an ICD lead removed for exit block, and three patients underwent TLE for infectious complications (two local, one systemic). ES assistance with laser or mechanical cutting sheaths was employed in the vast majority of cases (85.7%). All leads were removed completely. There were no major procedural complications. In five cases, lead reimplantation encountered low-amplitude R waves requiring multiple attempted lead positions before final successful implant. CONCLUSIONS: This is the first reported series of TLE in ARVC patients. TLE can be performed safely and effectively in patients with ARVC by experienced operators at high-volume centers with a low complication rate.
No takes yet. Share an insight, caveat, or question.
Maytin et al. (2013) conducted a cohort in Arrhythmogenic right ventricular cardiomyopathy (ARVC) (n=11). Transvenous lead extraction (TLE) of ICD leads was evaluated on Complete lead removal and procedural complications. Transvenous lead extraction in ARVC patients achieved 100% complete removal of all 22 leads across 14 procedures with 0% major procedural complications.
Synapse has enriched 10 related papers. Consider them for comparative context: