Key result
PV loop–guided biventricular pacing is linked to ~39% higher stroke work over baseline.
Why the study?
The clinical utility of pressure-volume loop analyses during pacemaker or ICD implantation for assessing optimal RV and LV lead positions required evaluation.
Does intraprocedural pressure-volume loop analysis optimize LV pacing site selection and acutely improve LV hemodynamic function in patients with heart failure and chronic RV apical pacing?
Observational (n=29)
Does intraprocedural pressure-volume loop analysis optimize LV pacing site selection and acutely improve LV hemodynamic function in patients with heart failure and chronic RV apical pacing?
Intraprocedural pressure-volume loop analysis identifies an optimal LV pacing site that differs from standard anatomical target veins in 45% of heart failure patients with chronic RV pacing, yielding significant acute hemodynamic improvements.
Answers are grounded in this paper and cite their sources.
Acute hemodynamic gains with PV-loop guided BiV pacing in RV-paced HF; hypothesis-generating pending randomized outcome trials.
AIMS: To evaluate the clinical utility of pressure-volume loop analyses during pacemaker/implantable cardioverter defibrillator (ICD) implantations to assess the optimal right ventricular (RV) and/or left ventricular (LV) lead position. METHODS AND RESULTS: 29 patients with heart failure and chronic RV apical pacing were studied. Stroke work (SW), LV ejection fraction (LVEF), cardiac output (CO), and LV dP/dt(max) were assessed using a conductance catheter in the LV during RV apical, RV outflow tract, single-site LV, and biventricular pacing at different left-sided pacing locations. Left ventricular ejection fraction was 34.3 +/- 9.8%. Compared with baseline, RV outflow tract pacing showed a small increase of 4.0 +/- 6.4% in LV dP/dt(max) and no improvement in SW, LVEF, or CO. In the optimal biventricular configuration, SW increased 39 +/- 41%, LVEF increased 22 +/- 13%, CO increased 16 +/- 16%, and LV dP/dt(max) increased 10 +/- 11% (all P < 0.05). In 45% of the patients, the optimal LV lead position was found at a different location as the 'first choice' postero-lateral or lateral target vein. CONCLUSION: Pressure-volume loop analysis during pacemaker/ICD implantations facilitates to determine the optimal LV pacing site. Patients with chronic RV pacing showed a significant acute improvement in LV function when LV pacing or biventricular pacing is applied.
No takes yet. Share an insight, caveat, or question.
Delnoy et al. (2008) conducted an observational in Heart failure and chronic RV apical pacing (n=29). Pressure-volume loop analysis to guide biventricular and single-site LV pacing vs. Baseline chronic RV apical pacing and RV outflow tract pacing was evaluated on Acute hemodynamic response including stroke work (SW), LV ejection fraction (LVEF), cardiac output (CO), and LV dP/dt(max) (p=<0.05). Optimal biventricular pacing guided by pressure-volume loops acutely increased stroke work by 39±41%, LVEF by 22±13%, and cardiac output by 16±16% vs baseline.
Synapse has enriched 10 related papers. Consider them for comparative context: