Key result
NIRS-derived StO2max correlates with microvascular shear metrics, but not with brachial artery FMD.
Why the study?
Microvascular responses contribute to the post-occlusive shear rate stimulus preceding flow-mediated dilation (FMD), and near-infrared spectroscopy (NIRS) characterizes aspects of microvascular function. However, the extent to which NIRS-derived indices relate to FMD remained unclear.
Cross-Sectional (n=20)
Answers are grounded in this paper and cite their sources.
Near-infrared spectroscopy-derived microvascular oxygenation metrics are associated with the reactive hyperemic shear stimulus (SR AUC) and peak hyperemic velocity, but not directly with brachial artery flow-mediated dilation, in healthy adults.
Microvascular responses contribute to the post-occlusive shear rate stimulus (quantified as the area under the curve [SR AUC]) that precedes flow-mediated dilation (FMD). While FMD is measured via ultrasonography, near-infrared spectroscopy (NIRS) characterizes aspects of microvascular function; however, the extent to which NIRS-derived indices relate to FMD remains unclear. Therefore, this investigation examined the associations between NIRS-derived metrics and peak hyperemic velocity (PHV), FMD, and SR AUC in 20 healthy adults. Skeletal muscle tissue oxygenation (StO2) was assessed using NIRS during a vascular occlusion test, while brachial artery diameter and blood velocity were measured using duplex ultrasound. NIRS-derived measures included the rate of resaturation (upslope), maximum resaturation (StO2max), and the area under the curve (AUC) of sustained hypersaturation. Pearson correlations and multiple linear regression were used to assess relationships between NIRS-derived measures, PHV, FMD, and SR AUC. There were no observed significant associations between NIRS-derived metrics and FMD (p > 0.08). In contrast, StO2max was significantly related to PHV (r = 0.530, p = 0.016) and SR AUC (r = 0.629; p = 0.004), and independently predicted SR AUC (β = 0.632, t = 3.893, p = 0.001). Baseline artery diameter (p = 0.346), SR AUC (p = 0.153), and upslope (p = 0.790) did not predict FMD (R = 0.668, adjusted R2 = 0.336, F(3,15) = 4.03, p = 0.027). These findings suggest that NIRS-derived metrics represent distinct yet complementary measures to FMD, while the association between StO2max and SR AUC suggests a relationship between microvascular function and the shear stimulus underlying FMD.
No takes yet. Share an insight, caveat, or question.
Pennartz et al. (2026) conducted a cross-sectional in Healthy adults (n=20). Near-infrared spectroscopy (NIRS)-derived microvascular oxygenation metrics (StO2max, upslope, hypersaturation AUC) was evaluated on Associations between NIRS-derived metrics and peak hyperemic velocity (PHV), flow-mediated dilation (FMD), and shear rate area under the curve (SR AUC) (r = 0.629 (StO2max vs SR AUC), p=0.004). NIRS-derived StO2max correlated with shear rate AUC and peak hyperemic velocity, but not with brachial artery FMD.
Synapse has enriched 10 related papers. Consider them for comparative context: