Key result
Femoral artery flow-mediated dilation showed a significant moderate correlation with tibial anterior muscle oxygen resaturation rate in healthy young individuals.
Why the study?
Because microvascular responsiveness can influence upstream conduit artery hemodynamics, the study investigated whether a correlation exists between FMD and muscle StO2 parameters.
Is there a correlation between femoral artery flow-mediated dilation and muscle oxygen saturation parameters in healthy, young individuals?
Cross-Sectional (n=16)
Is there a correlation between femoral artery flow-mediated dilation and muscle oxygen saturation parameters in healthy, young individuals?
Femoral artery flow-mediated dilation moderately correlates with tibial anterior muscle oxygen saturation parameters, linking macro- and microvascular function assessments in healthy young individuals.
Answers are grounded in this paper and cite their sources.
Suggests macro-microvascular linkage in healthy youth; hypothesis-generating for integrated vascular assessment in disease.
Flow-mediated dilation (FMD) and muscle oxygen saturation (StO2) are measurements utilized to assess macro- and microvascular function, respectively. Macro- and microvascular dysfunction may occur differently depending on the clinical condition. Since microvascular responsiveness can influence upstream conduit artery hemodynamics, the present study aimed to investigate whether a correlation between FMD and muscle StO2 parameters exists. Sixteen healthy, young individuals were enrolled in this study. Femoral artery FMD and tibial anterior muscle StO2 were evaluated by ultrasound and near-infrared spectroscopy, respectively. The FMD and muscle StO2 parameters were assessed by employing a vascular occlusion test (VOT). The oxygen resaturation rate was determined by calculating the upslope of StO2 immediately after occlusion and the magnitude of reperfusion as the difference between the highest and lowest StO2 value achieved during the reperfusion phase. The oxygen desaturation rate and the magnitude of desaturation during the VOT were also evaluated. A significant correlation between the FMD and oxygen resaturation rate (r = 0.628; p = 0.009), magnitude of reperfusion (r = 0.568; p = 0.022), oxygen desaturation rate (r = −0.509; p = 0.044), and magnitude of desaturation (r = 0.644; p = 0.007) was observed. This study demonstrated a moderate association between the femoral artery FMD and tibial anterior StO2 parameters in young individuals.
No takes yet. Share an insight, caveat, or question.
Pinheiro et al. (2023) conducted a cross-sectional in Healthy (n=16). Femoral artery flow-mediated dilation (FMD) was evaluated on Correlation between FMD and oxygen resaturation rate (r = 0.628, p=0.009). Femoral artery flow-mediated dilation showed a significant moderate correlation with tibial anterior muscle oxygen resaturation rate in healthy young individuals.
Synapse has enriched 10 related papers. Consider them for comparative context: