Composite fan blades are subjected to interlaminar failure risks under complex service loads, and reliable prediction of damage evolution is essential for structural safety assessment. This study investigated the interlaminar shear failure behavior of resin‐matrix composites and its relevance to composite fan‐blade tenon structures. Multi‐stage short‐beam shear (SBS) tests, digital image correlation (DIC), and microscopic observation were used to relate the non‐linear load–displacement response to the initiation and propagation of interlaminar delamination. To represent the residual load‐bearing capacity after delamination, a non‐linear cohesive constitutive model incorporating the through‐thickness compression (TTC) effect was developed. In SBS simulations, the model reproduced the linear elastic, non‐linear, and sub‐linear response stages, with displacement‐field errors limited to 3.4% relative to DIC measurements. The model was further applied to tensile failure analysis of a full‐scale composite tenon structure. The predicted progressive delamination loads differed from the experimental values by less than 3%, and the simulated failure locations matched the observed machined/cushion‐layer and main‐ply delamination sites. These results support the use of the proposed Cohesive‐TTC model for delamination assessment of composite structures under coupled compression‐shear loading.