Answers are grounded in this paper and cite their sources.
Purpose Powder-based metal additive manufacturing (AM) suffers from low productivity and lack-of-fusion defects that can contribute to build-direction-dependent properties. Laser Wire Directed Energy Deposition (LW-DED) is a promising alternative, but its horizontal and vertical tensile responses remain insufficiently characterized. This study aims to establish a stable processing condition for LW-DED Ti-6Al-4V and then quantitatively evaluate the tensile-property differences between the horizontal and vertical orientations under the selected condition. Specimens conforming to the american society for testing and materials (ASTM) E8/E8M-08 subsize geometry were used to improve the rigor and comparability of the mechanical-property data. Design/methodology/approach Horizontal and vertical tensile behavior of LW-DED Ti-6Al-4V was evaluated using ASTM E8/E8M-08 specimens. A two-step process-window optimization on cubic specimens identified the stable volumetric energy density (VED) range and compared 45° and bi-directional infill strategies. Horizontal bars were extracted from 90 × 12 × 15 mm walls, and vertical bars from a 30 × 30 × 90 mm hollow pillar designed to suppress heat-accumulation-induced warping. Microstructure was analyzed by optical microscopy (OM), scanning electron microscopy (SEM) and electron backscatter diffraction (EBSD) on the XZ plane. Findings The 45°-Low VED condition yielded the most stable bead morphology, the highest mean elongation and low elongation scatter. Horizontal and vertical specimens showed YS/UTS/EL of 849.7/953.9 MPa/12.3% and 849.3/931.4 MPa/11.4%, respectively—differences of only ∼2.4% in ultimate tensile strength (UTS) and 0.9%p in elongation. EBSD revealed comparable basal texture (24.3 vs 26.5) and identical kernel average misorientation (1.5°), with modest differences in a grain size (6.2 vs 7.7 µm) and HAGB fraction (82.6% vs 73.6%). Limited directional differences were observed under the selected processing condition and the investigated specimen geometries. Originality/value This study combines process-window optimization with a quantitative comparison of the horizontal and vertical tensile responses of LW-DED Ti-6Al-4V under the selected 45°-Low VED condition. The observed directional differences are interpreted through OM, SEM and EBSD analyses. The use of ASTM-conforming tensile specimens improves the reliability of the measurements and facilitates comparison with previously reported AM data.
No takes yet. Share an insight, caveat, or question.
Lee et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: