Key result
Dual-chamber leadless RVP increases LV mechanical dyssynchrony ~3.7-fold versus intrinsic conduction on SPECT.
Why the study?
Right ventricular myocardial pacing can produce non-physiological ventricular activation and mechanical dyssynchrony even when atrioventricular synchrony is preserved by a dual-chamber leadless pacing system.
Does atrial-sensed right ventricular pacing via a dual-chamber leadless pacemaker increase left ventricular mechanical dyssynchrony on gated SPECT phase analysis compared with intrinsic ventricular conduction in a patient with 2:1 atrioventricular block?
Case Report (n=1)
No
Does atrial-sensed right ventricular pacing via a dual-chamber leadless pacemaker increase left ventricular mechanical dyssynchrony on gated SPECT phase analysis compared with intrinsic ventricular conduction in a patient with 2:1 atrioventricular block?
Even when atrioventricular synchrony is preserved with a dual-chamber leadless pacemaker, right ventricular myocardial pacing can induce marked electrical and mechanical dyssynchrony that can be objectively quantified using gated myocardial perfusion SPECT phase analysis.
Answers are grounded in this paper and cite their sources.
Gated SPECT detects RV pacing-induced dyssynchrony after dual-chamber leadless implantation; hypothesis-generating and should not yet change practice.
Right ventricular (RV) myocardial pacing can produce non-physiological ventricular activation and mechanical dyssynchrony even when atrioventricular synchrony is preserved by a dual-chamber leadless pacing system.We report a 79-year-old man receiving maintenance hemodialysis who underwent implantation of an AVEIR DR Dual Chamber Leadless Pacemaker System for 2:1 atrioventricular block.During atrial-sensed RV pacing, the QRS duration increased from 142 ms at baseline to 202 ms.Transthoracic echocardiography during intrinsic ventricular conduction showed no visually apparent intraventricular mechanical dyssynchrony, whereas follow-up echocardiography 11 days after implantation demonstrated left ventricular wall motion suggestive of mechanical dyssynchrony during RV pacing.Gated myocardial perfusion single-photon emission computed tomography (SPECT) phase analysis performed during ventricular pacing demonstrated marked mechanical dyssynchrony, with a phase standard deviation of 33.7 degrees, a 95% histogram bandwidth of 113.0 degrees, and a phase entropy of 76.34 %.Several days later, device programming was modified to permit intrinsic ventricular conduction, and a second SPECT study was performed during intrinsic 2:1 atrioventricular conduction at 39-40 beats/min, with ventricular backup pacing set at 30 beats/min.The corresponding phase indices were substantially lower at 9.1 degrees, 35.0 degrees, and 44.55%, respectively.Because the patient's overall clinical status and hemodialysis-related conditions differed between the two examinations, the observed numerical differences cannot be attributed to pacing alone.Nevertheless, the concordant and marked changes across all phase indices provide objective evidence supporting RV pacing-associated mechanical dyssynchrony.This case highlights the potential value of gated SPECT phase analysis as a quantitative method for assessing mechanical synchrony after leadless pacemaker implantation.
No takes yet. Share an insight, caveat, or question.
Kobayashi et al. (2026) conducted a case report in 2:1 atrioventricular block and complete right bundle branch block on maintenance hemodialysis (n=1). Atrial-sensed right ventricular pacing via AVEIR DR dual-chamber leadless pacemaker vs. Intrinsic 2:1 atrioventricular conduction (backup pacing at 30 bpm) was evaluated on Left ventricular mechanical dyssynchrony measured by gated SPECT phase standard deviation (degrees). Right ventricular pacing via a dual-chamber leadless pacemaker increased gated SPECT phase standard deviation to 33.7° compared to 9.1° during intrinsic conduction.