Key result
Balloon aortic valvuloplasty cuts mean systolic gradient by ~45 mm Hg immediately post-procedure.
Why the study?
Many adult patients with severe calcific aortic stenosis have unacceptably high operative risk, contraindications to thoracic surgery, or refuse surgical valve replacement, motivating evaluation of percutaneous transluminal balloon valvuloplasty.
Does percutaneous transluminal balloon valvuloplasty improve aortic valve hemodynamic parameters (mean systolic gradient and aortic valve area) in adult patients with severe calcific aortic stenosis at high surgical risk?
Observational (n=92)
Does percutaneous transluminal balloon valvuloplasty improve aortic valve hemodynamic parameters (mean systolic gradient and aortic valve area) in adult patients with severe calcific aortic stenosis at high surgical risk?
Answers are grounded in this paper and cite their sources.
Percutaneous transluminal balloon valvuloplasty significantly reduces the transvalvular gradient and increases aortic valve area and ejection fraction immediately after the procedure in high-risk elderly patients with severe calcific aortic stenosis.
Percutaneous transluminal balloon valvuloplasty was attempted in 92 adult patients with severe calcific aortic stenosis. The mean age was 75 +/- 11 years (range 38 to 91) and 35 patients were more than 80 years old. Most of the patients were severely disabled; 66 were in New York Heart Association functional class III or IV, 27 had syncopal attacks and 21 had severe angina pectoris. Because of unacceptably high surgical risk or contraindication to thoracic surgery, 42 patients could not be considered for valve replacement. Other patients either were in a category of high operative risk or refused the surgical intervention. Valvuloplasty was performed by way of the femoral route (82 patients) or the brachial route (10 patients). Catheters of size 15, 18 and 20 mm were successively placed across the aortic valve and three inflations were usually done with each of them, lasting 80 seconds on average, until a decrease in peak to peak systolic pressure gradient to 40 mm Hg or less was attained, a result considered satisfactory. The inflated balloons were not totally occlusive in most cases and clinical tolerance of inflation was good. Valvuloplasty resulted in a reduction of mean systolic gradient from 75 +/- 26 to 30 +/- 13 mm Hg (p less than 0.001); the final gradient was less than 40 mm Hg in 78 patients. Mean calculated aortic valve area increased from 0.49 +/- 0.17 to 0.93 +/- 0.36 cm2 (p less than 0.001). Immediately after the procedure, ejection fraction increased from 48 +/- 16 to 51 +/- 16% (p less than 0.01).(ABSTRACT TRUNCATED AT 250 WORDS)
No takes yet. Share an insight, caveat, or question.
Cribier et al. (1987) conducted an observational in Severe calcific aortic stenosis (n=92). Percutaneous transluminal balloon valvuloplasty vs. Pre-procedure baseline was evaluated on Mean systolic pressure gradient (mm Hg) and calculated aortic valve area (cm2) (p=<0.001). Percutaneous balloon valvuloplasty reduced mean systolic gradient from 75 to 30 mm Hg and increased aortic valve area from 0.49 to 0.93 cm2.
Synapse has enriched 10 related papers. Consider them for comparative context: