Cardiac-CT detects persistent LAA leaks after AMPLATZER closure in ~62% of patients, outperforming TEE.
Why the study?
Detecting peri-device leaks by TEE after percutaneous LAA closure with the AMPLATZER Cardiac Plug is challenging, and inconsistent data have left the frequency of leaks unclear.
Observational (n=24)
Answers are grounded in this paper and cite their sources.
Small peri-device leaks frequent on CT after ACP; leaves open clinical relevance and optimal imaging follow-up.
OBJECTIVES: The aim of the study was to examine frequency, size, and localization of peri-device leaks after percutaneous left atrial appendage (LAA)-closure with the AMPLATZER-Cardiac-Plug (ACP) by using a multimodal imaging approach, i.e. combined cardiac-CT and TEE follow-up. BACKGROUND: Catheter-based LAA-occlusion using ACP aims to reduce the risk of stroke in patients with atrial fibrillation. Detection of peri-device leaks after ACP implantation by TEE is challenging, the few available data are inconsistent and the frequency of LAA leaks after ACP implantation remains therefore unclear. METHODS: Cardiac-CT using a multi-phase protocol and a second-generation dual-source-CT-system was performed in 24 patients with non-valvular atrial fibrillation starting 3 months after LAA-closure by ACP. Color Doppler multiplane TEE was used to evaluate peri-device flow. RESULTS: Cardiac-CT follow-up detected any persistent LAA contrast filling in 62% of patients (n = 15), but leak-sizes were small (1.5 ± 1.4 mm). Peri-device leaks were almost exclusively localized at the posterior portion of the LAA-orifice (>90%). TEE follow-up revealed peri-device flow in 36% of patients (jet-sizes: ≤ 4 mm). ACP-lobe compression (>10%) and perpendicular ACP-lobe orientation to the LAA-neck axis, that was also dependent on LAA anatomy, were substantially more frequent in patients with complete LAA closure. CONCLUSION: The present study evaluates for the first time peri-device flow after LAA closure by ACP using a combined cardiac-CT and TEE follow-up. Persistent LAA-perfusion was frequently detected, leak-sizes were small and were less frequent when lobe compression was >10% and lobe orientation was perpendicular to the LAA-neck axis, that was also related to the LAA anatomy. The clinical significance of these small leaks after LAA-closure using ACP needs to be further evaluated in future studies.
No takes yet. Share an insight, caveat, or question.
Jaguszewski et al. (2014) conducted an observational in Non-valvular atrial fibrillation undergoing percutaneous left atrial appendage closure (n=24). Percutaneous left atrial appendage closure with AMPLATZER Cardiac Plug evaluated by cardiac-CT vs. Transesophageal echocardiography (TEE) evaluation was evaluated on Persistent LAA contrast filling / peri-device flow. Combined cardiac-CT and TEE after LAA closure with the AMPLATZER Cardiac Plug detected persistent LAA contrast filling in 62% of patients on CT and peri-device flow in 36% on TEE.
Synapse has enriched 10 related papers. Consider them for comparative context: