Key result
Percutaneous coronary sinus mitral annuloplasty reshapes the annulus to improve leaflet coaptation in functional mitral regurgitation.
Why the study?
Functional mitral regurgitation is associated with worse outcomes, and many patients with severe mitral regurgitation are denied or refused surgery, making less invasive percutaneous coronary sinus annuloplasty devices an attractive alternative to review.
This review discusses contemporary percutaneous coronary sinus mitral annuloplasty devices and the anatomical relationships between the coronary sinus, mitral annulus, and coronary arteries for treating functional mitral regurgitation.
Answers are grounded in this paper and cite their sources.
Anatomical variations necessitate individualized device selection; leaves open the need for randomized trials before clinical adoption in functional mitral regurgitation.
Mitral regurgitation has become recognized as an important health problem. More specifically, functional mitral regurgitation is associated with worse outcomes in heart failure, postmyocardial infarction, and perioperative coronary artery bypass surgery patients. Many patients with severe mitral regurgitation are denied or refused mitral valve surgery. A less invasive procedure with possibly fewer potential complications may thus be attractive for patients with severe mitral regurgitation. Devices used for coronary sinus (CS) mitral annuloplasty are directed toward patients with functional mitral regurgitation. Because of its easy accessibility and close relationship to the posterior mitral annulus (MA), alterations of the CS geometry with percutaneous devices may translate to displacement of the posterior annulus and correct mitral leaflet coaptation. This review will focus on the contemporary CS annuloplasty devices: (1) Edwards MONARC system; (2) Cardiac Dimensions CARILLON; and (3) Viacor Shape Changing Rods system. In addition, important information obtained from recent imaging studies describing the relationship between the CS, MA, and coronary arteries will be reviewed.
No takes yet. Share an insight, caveat, or question.
Piazza et al. (2007) conducted a review in Functional mitral regurgitation. Coronary sinus mitral annuloplasty devices (Edwards MONARC system, Cardiac Dimensions CARILLON, Viacor Shape Changing Rods system) was evaluated. Percutaneous coronary sinus mitral annuloplasty devices alter coronary sinus geometry to displace the posterior mitral annulus and correct mitral leaflet coaptation in functional mitral regurgitation.