Answers are grounded in this paper and cite their sources.
To address the demand for high-precision measurement of large-scale gratings in precision optical manufacturing and metrology, this study proposes a single-period evaluation method based on a prism-grating interferometer and pseudo-phase-stepping interferometry. Unlike existing four-step phase-stepping or least-squares iterative methods, this work employs the Hariharan algorithm, which is robust to phase-step errors, and constructs pseudo phase steps by numerically stepping the interference signal. The interferometer uses a symmetric optical path with zero optical path difference, effectively suppressing environmental disturbances. Experiments were performed on a 300 mm×70 mm 2D grating with a period of 833 nm. For a single-period calculation length (833 nm), the peak-to-valley (PV) values are 33.11 and 38.85 nm, respectively; when the calculation length is increased to 1 mm, the PV values decrease to 29.02 and 31.04 pm, respectively, achieving picometer-level average period measurement. Error analysis of the pseudo phase-stepping algorithm and air refractive index fluctuations is provided to explain the single-period fluctuations. This work achieves long-travel single-period and 1 mm-range comparative period measurements on a large-scale grating, showing significant improvements over recent work in measurement dimension, analysis scale, and completeness of error analysis.
No takes yet. Share an insight, caveat, or question.
Zhang et al. (2026) studied this question.