Key result
Automated ECG analysis matches human readers with ~80% accuracy for detecting prior MI.
Why the study?
The comparative diagnostic performance of automated 12-lead ECG analysis using the ECG Treatment Module versus human ECG interpretation for detecting prior myocardial infarction against a cardiovascular magnetic resonance reference standard needed evaluation.
Does automated 12-lead ECG analysis using the ECG Treatment Module (ETM) improve the diagnostic detection of prior myocardial infarction compared to human ECG interpretation in patients referred for CMR evaluation of coronary artery disease or cardiomyopathy?
Observational (n=1,038)
Blinded assessors
Does automated 12-lead ECG analysis using the ECG Treatment Module (ETM) improve the diagnostic detection of prior myocardial infarction compared to human ECG interpretation in patients referred for CMR evaluation of coronary artery disease or cardiomyopathy?
Automated 12-lead ECG analysis using the ETM algorithm provides diagnostic accuracy comparable to human cardiologists for detecting prior myocardial infarction against a CMR reference standard, though its low sensitivity (43.8%) prevents reliable exclusion of myocardial scar.
Answers are grounded in this paper and cite their sources.
Automated ECG matches human accuracy for prior MI detection but misses over half; leaves open routine use pending prospective validation.
Purpose To compare automated 12-lead ECG analysis using the ECG Treatment Module (ETM) with human ECG interpretation for detecting prior myocardial infarction (pMI), using cardiovascular magnetic resonance (CMR) as the reference standard. Methods Consecutive patients referred for CMR evaluation of coronary artery disease or cardiomyopathy were included. pMI was centrally adjudicated using Late Gadolinium Enhancement (LGE). LGE was assessed using the 17-segment model for ischaemic pattern, degree of transmurality, and presence of non-ischaemic LGE. ECGs were automatically analysed using the ETM (ETM-2.8.0, Schiller AG, Switzerland). At least two independent cardiologists, blinded to all clinical and imaging data, interpreted the ECGs for pMI according to the fourth universal definition of myocardial infarction. Results Among 1038 patients, automated ECG analysis achieved an overall diagnostic accuracy of 80.3% (77.7% - 82.6%) for pMI detection with a specificity of 89.4% (87.1% - 91.3%) and a sensitivity of 43.8% (37.2% - 50.5%). Compared with human readers, ETM demonstrated similar overall diagnostic accuracy. Without ECG confounders such as bundle branch blocks, the ETM algorithm outperformed humans; with ECG confounders, humans outperformed the algorithm. Transmural infarctions were detected more frequently than subendocardial infarctions (53.9% vs 34.0%, p=0.0058), and detection was higher in infarctions with >50% transmurality (p=0.0464). Of the 179 patients with automatically presumed pMI, 50.8% had an ischaemic LGE pattern and 27.9% had non-ischaemic LGE. Overall, 56.2% of CMR-confirmed pMIs were missed, most commonly in the lateral segments (61.1%). Conclusions Automated ECG analysis using ETM demonstrated diagnostic performance comparable to human readers for detection of pMI, but limited sensitivity precludes reliable exclusion of myocardial scar.
No takes yet. Share an insight, caveat, or question.
Segeroth et al. (2026) conducted an observational in Prior myocardial infarction (n=1,038). Automated 12-lead ECG analysis using the ECG Treatment Module (ETM) vs. Human ECG interpretation by independent cardiologists was evaluated on Diagnostic accuracy for detecting prior myocardial infarction using CMR as the reference standard (95% CI 77.7-82.6). Automated ECG analysis using ETM achieved 80.3% diagnostic accuracy for prior MI detection, comparable to human readers.