Corrosion that initiates at organic-coating defects spreads beneath the coating that still appears intact, so the metal loss is hidden and revealed only by destructively removing the coating. Prior work established a blister–corrosion relationship consistent across accelerated and field exposure, but whether it predicts specimen-level hidden corrosion within a single field regime—relevant to inspection—was untested. Using a paired four-environment dataset of defective painted steel characterised by 3D laser profilometry, we test this within a physics-informed Bayesian framework. Out-of-sample within the field, blister volume alone is non-predictive ( R ² ≈ 0); adding the coating thickness restores prediction (leave-one-out R ² ≈ 0.56) with calibrated credible intervals (≈ 87% coverage at the 90% level) that generalise to coatings and sites not seen in training. The reason is mechanical: for a given corrosion volume, a stiffer, thicker coating spreads the rust into a wider, lower blister, so coating mechanics set the blister height. These findings refine rather than replace the transferable relationship—a first-order volumetric law plus a second-order coating-mechanics term that governs the low-damage field regime. Because the calibrated intervals sharpen as inspections accumulate, the framework supports sequential, risk-based maintenance and a non-destructive route to hidden-corrosion assessment that improves over a structure's service life.