Key result
Stents longer than 40 mm are linked to higher 3-month major cardiovascular events and troponin elevation.
Why the study?
Stent length is a potential predictor of adverse outcomes after PCI in patients with stable CAD, but its impact on PCI-induced myocardial injury and early clinical outcomes remains uncertain.
Does longer stent length (>40 mm or 20-40 mm vs <20 mm) increase PCI-induced myocardial injury and short-term major adverse cardiac events in patients with stable coronary artery disease undergoing elective single-vessel PCI?
Observational (n=200)
No
Does longer stent length (>40 mm or 20-40 mm vs <20 mm) increase PCI-induced myocardial injury and short-term major adverse cardiac events in patients with stable coronary artery disease undergoing elective single-vessel PCI?
In patients with stable CAD undergoing elective single-vessel PCI, implanting longer stents (>40 mm) is associated with greater peri-procedural myocardial injury and higher 3-month MACE, whereas larger stent diameters reduce MACE risk.
Answers are grounded in this paper and cite their sources.
Longer stents may increase peri-procedural risk in elective PCI; leaves open whether length independently drives MACE or warrants length minimization.
Background and aim: Stent length is a potential predictor of adverse results following percutaneous coronary intervention (PCI), particularly in cases with stable coronary artery disease (CAD). However, its impact on myocardial injury and early clinical outcomes remains uncertain. This research aimed to assess the effect of stent length on PCI-induced myocardial necrosis and short-term clinical results in cases with stable CAD. Methods: This prospective observational study included 200 patients undergoing elective single-vessel PCI at Assiut Heart University Hospital. Patients were categorized by stent length: short (<20 millimeters), intermediate (20–40 millimeters), and long (>40 mm). Serial cardiac troponin-I (cTnI) measurements, ECG, echocardiography, and clinical follow-up were performed in-hospital and at 3 months post-PCI. Outcomes assessed included myocardial injury (cTnI elevation), hemodynamic instability, arrhythmias, and major adverse cardiac events (MACE). Results: Troponin levels rose significantly 6 hours post-PCI, particularly with longer stents. While echocardiographic recovery (EF and wall motion) improved across all groups, longer stents were significantly related to higher MACE at 3 months (p=0.041). ROC analysis showed poor predictive value of troponin for MACE (AUC <0.6). Larger stent diameters were associated with reduced MACE risk (p=0.046) and improved stability, whereas smaller diameters were associated with increased arrhythmia risk. Conclusion: Longer stents are associated with greater myocardial injury and higher short-term MACE. Stent diameter appears to influence post-procedural stability and adverse events. These findings highlight the importance of optimizing stent size selection during PCI.
No takes yet. Share an insight, caveat, or question.
Fouad et al. (2026) conducted an observational in Stable coronary artery disease undergoing percutaneous coronary intervention (n=200). Long stent (>40 mm) and intermediate stent (20-40 mm) vs. Short stent (<20 mm) was evaluated on Major adverse cardiac events (MACE) and myocardial injury (cTnI elevation) at 3 months (p=0.041). Longer stents (>40 mm) during elective single-vessel PCI were associated with greater post-procedural troponin elevation and higher major cardiovascular events at 3 months.