This study establishes a method for detecting neutralizing antibodies in livestock, suggesting it may replace traditional virus neutralization tests.
Foot-and-mouth disease (FMD) is a highly contagious viral disease affecting cloven-hoofed animals, posing significant threats to global livestock industries. Post-vaccination neutralizing antibody levels reflect vaccine efficacy, but traditional virus neutralization tests (VNT) for detecting neutralizing antibodies requires restrictive biocontainment facilities to handle live virus, is time-consuming and laborious. In this study, we successfully established a high-efficiency magnetic particle-based chemiluminescence immunoassay (MP-CLIA) using two previously characterized monoclonal antibodies (W125 and W145) generated through single B cell antibody technology. The MP-CLIA method exhibited a sensitivity of 95.93% and specificity of 100%, with a cut-off value of 41.395 activity units (U) by detecting the known 221 positive and 122 negative sera. The positive/negative coincidence rate between the MP-CLIA and VNT was 92.2% and the kappa coefficient was 78.19%, indicating a relatively high level of consistency. When integrated with a fully automated chemiluminescence immunoassay analyzer, this method only takes 20 min for a single test. These results show that MP-CLIA is a promising tool for the safe, rapid, and fully automatic detection of neutralizing antibodies against FMD virus (FMDV) serotype A.
No takes yet. Share an insight, caveat, or question.
Sun et al. (2025) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: