Key result
His bundle pacing shortens QRS by ~48 ms and improves LVEF in wide-QRS heart failure.
Why the study?
To evaluate systematically the feasibility and effectiveness of His Bundle Pacing for cardiac resynchronization therapy.
Does His Bundle Pacing improve QRS duration, LVEF, and NYHA class in patients with heart failure and wide QRS complex?
Meta-Analysis (n=555)
Does His Bundle Pacing improve QRS duration, LVEF, and NYHA class in patients with heart failure and wide QRS complex?
His bundle pacing is a feasible and effective strategy for cardiac resynchronization therapy, significantly improving QRS duration, LVEF, and NYHA class in heart failure patients.
Answers are grounded in this paper and cite their sources.
Supports HBP as CRT alternative in HF with wide QRS; confirms QRS and LVEF benefits versus baseline in meta-analysis.
Objective: To evaluate systematically the feasibility and effectiveness of His Bundle Pacing (HBP) for cardiac resynchronization therapy.Methods: A comprehensive search was conducted in PubMed, EMbase, WOS, Cochrane Library, Medline, and SinoMed for studies published between December 2003 and December 2023.Primary clinical outcomes included implantation success, QRS wave duration, pacing threshold, left ventricular ejection fraction (LVEF), left ventricular end-diastolic diameter (LVEDD), New York Heart Association (NYHA) cardiac function class, and complications.Data were extracted and summarized, and meta-analysis was performed by Revman 5.3 software.Results: Fourteen studies involving a total of 555 patients were included.The overall success rate for HBP implantation was 83.2% (462/555).Compared to baseline values, QRS duration was significantly reduced (MD=48.29,95% CI: 45.20 to 51.38, P<0.01,I 2 =85%), LVEF was significantly increased (MD=-13.62,95% CI: -15.46 to -11.79, P<0.01,I 2 =74%), LVEDD was smaller (MD=5.83,95% CI: 4.44-7.22,P<0.01,I 2 =78.2%), and NYHA showed significant improvement (MD=1.24,95% CI: 1.14-1.35,P<0.01,I 2 =97.2%).At follow-up, pacing threshold increased (MD=-0.28,95% CI: -0.43 to -0.12, P<0.01,I 2 =0%), and pacing impedance decreased (MD=51.62,95% CI: 23.67 to 79.56, P<0.01,I 2 =56%).Conclusion: HBP is effective for cardiac resynchronization therapy.HBP significantly reduces QRS duration and improves LVEF in heart failure patients.
No takes yet. Share an insight, caveat, or question.
Zhigang You (2024) conducted a meta-analysis in Heart failure with wide QRS complex (n=555). His Bundle Pacing (HBP) vs. Baseline was evaluated on QRS duration (MD 48.29, 95% CI 45.20 to 51.38, p=<0.01). His bundle pacing significantly reduced QRS duration (MD 48.29) and improved left ventricular ejection fraction compared to baseline in patients with heart failure and a wide QRS complex.