Key result
CCM linked to ~37% lower six-year mortality versus no device in chronic HF.
Why the study?
Data are limited regarding the effect of cardiac contractility modulation on long-term outcomes like mortality and hospitalization rates in chronic heart failure.
Does cardiac contractility modulation device placement reduce mortality in patients with chronic heart failure?
Comparison
CCM device placement vs without CCM device
Design
Retrospective propensity score-matched cohort study
Follow-up
6 years
Authors
Loading...
CCM was associated with lower mortality; hypothesis-generating and should not yet change practice without randomized confirmation.
Cohort (n=736)
Yes
Does cardiac contractility modulation device placement reduce mortality in patients with chronic heart failure?
Effect estimate: RR 0.63 (95% CI 0.43-0.92)
Absolute Event Rate: 15.47% vs 20.9%
Cardiac contractility modulation device placement is associated with significantly decreased long-term mortality at 6 years compared to no CCM in patients with chronic heart failure.
Khadka et al. (2026) conducted a cohort in Chronic heart failure (n=736). Cardiac contractility modulation (CCM) device vs. No CCM device was evaluated on All-cause mortality at 6 years (RR 0.63, 95% CI 0.43-0.92). Cardiac contractility modulation was associated with lower 6-year mortality compared to no device in chronic heart failure (15.47% vs 20.90%; RR 0.63, 95% CI 0.43-0.92).