Key result
Transcatheter tricuspid valve repair treats severe isolated functional TR and chronic right heart failure.
Why the study?
A patient with severe functional TR and chronic right heart failure refractory to maximized medical therapy was declined for open heart surgery because of relevant operative risk, prompting compassionate-use transcatheter tricuspid annuloplasty with the Mitralign system.
Case Report (n=1)
No
This case report demonstrates the feasibility of transcatheter partial annuloplasty using the Mitralign system to significantly reduce isolated severe functional tricuspid regurgitation and improve symptoms in a high-risk surgical patient.
Answers are grounded in this paper and cite their sources.
Single-case report suggests procedural feasibility in isolated functional TR; leaves open safety, durability, and need for trials.
A 60-year-old man was hospitalized with chronic right heart failure, ascites, and peripheral oedema. He had a history of ischaemic cardiomyopathy without need for revascularization, persistent atrial fibrillation, and renal failure. Echocardiography showed moderately reduced left ventricular ejection fraction of 35–40%, without relevant AV or MV disease, severe right heart dilatation, and severe functional tricuspid regurgitation (TR) causing chronic right heart volume overload (PISA 1.5 cm, EROA 53 mm 2 ) ( Panel A ). Further diagnostic work up including right heart catheterization excluded severe pulmonary hypertension and other causes for right heart decompensation. The patient was discussed within the heart team and open heart surgery was declined because of relevant operative risk for isolated tricuspid valve repair (EuroSCORE 13.08%). Because of chronic right heart failure despite maximized medical therapy, invasive tricuspid annuloplasty was planned with the Mitralign system on a compassionate use basis. The intervention was performed under general anaesthesia with fluoroscopic and 3D TEE guidance ( Panels B – E ). During the intervention a guiding catheter was advanced via the right jugular vein into the right ventricle. The tricuspid annulus was crossed with a radio frequency wire in the region of the septal–lateral commissure ( Panel B ). After placement of the first pledget in the septal annular region, another pledget was placed lateral aiming to a distance of ∼25 mm ( Panel C ). Finally, annuloplasty was performed under TEE and fluoroscopic control, and the pledgets were locked in place ( Panels D and E ). This procedure led to a significant reduction of all TR defining parameters (PISA 0.56 cm, EROA 22 mm 2 , Panel F ) followed by reduction of heart failure symptoms. The patient was discharged on Day 8 after the procedure in functional NYHA class II. This case illustrates a new interventional strategy for minimally invasive TR reduction with partial annuloplasty of the posterior tricuspid valve annulus by the use of the Mitralign system. M.M. acquired the data, performed statistical analysis, and drafted the manuscript. N.W. handled funding and supervision. C.H. conceived and designed the research. G.N. made critical revision of the manuscript for key intellectual content.
No takes yet. Share an insight, caveat, or question.
Malasa et al. (2015) conducted a case report in Isolated severe functional tricuspid regurgitation and chronic right heart failure (n=1). Transcatheter tricuspid valve annuloplasty with the Mitralign system was evaluated on Tricuspid regurgitation severity (EROA and PISA) and heart failure symptoms. Transcatheter tricuspid annuloplasty with the Mitralign system reduced EROA from 53 to 22 mm² and PISA from 1.5 to 0.56 cm, improving symptoms to functional class II by Day 8.
Synapse has enriched 10 related papers. Consider them for comparative context: