Key result
MobiusHD baroreflex amplification in HFrEF is linked to a ~17-point KCCQ improvement and higher LVEF.
Why the study?
Endovascular baroreflex amplification with the MobiusHD device was designed to reduce sympathetic overactivity contributing to progressive heart failure with reduced ejection fraction.
Does endovascular baroreflex amplification with the MobiusHD device improve symptoms, exercise capacity, and biomarkers in patients with HFrEF?
Observational (n=29)
Does endovascular baroreflex amplification with the MobiusHD device improve symptoms, exercise capacity, and biomarkers in patients with HFrEF?
Endovascular baroreflex amplification with the MobiusHD device appears safe and may improve quality of life, exercise capacity, and LVEF in patients with HFrEF.
Should not change HFrEF practice; hypothesis-generating for MobiusHD and requires randomized confirmation.
Background: Endovascular baroreflex amplification with the MobiusHD, a self-expanding stent-like device that is implanted in the internal carotid artery, was designed to reduce the sympathetic overactivity that contributes to progressive heart failure with reduced ejection fraction. Methods: Symptomatic patients (New York Heart Association class III) with heart failure with reduced ejection fraction (left ventricular ejection fraction [LVEF] ≤40%) despite guideline directed medical therapy and n-terminal pro-B type natriuretic peptide (NT-proBNP) levels ≥400 pg/mL in whom carotid ultrasound and computed tomographic angiography demonstrated absence of carotid plaque were enrolled. Baseline and follow-up measures included 6-minute walk distance (6MWD), Kansas City Cardiomyopathy Questionnaire overall summary score (KCCQ OSS), and repeat biomarkers and transthoracic echocardiography. Results: Twenty-nine patients underwent device implantation. The mean age was 60.6 ± 11.4 years, and all had New York Heart Association class III symptoms. Mean KCCQ OSS was 41.4 ± 12.7, mean 6MWD was 216.0 ± 43.7 m, median NT-proBNP was 1005.9 pg/mL (894, 1294), and mean LVEF was 34.7 ± 2.9%. All device implantations were successful. Two patients died (161 days and 195 days) and one stroke occurred (170 days) during follow-up. For the 17 patients with 12-month follow-up, mean KCCQ OSS improved by 17.4 ± 9.1 points, mean 6MWD increased by 97.6 ± 51.1 meters, a mean 28.4% reduction from the baseline NT-proBNP concentration was found, and mean LVEF improved by 5.6% ± 2.9 (paired data). Conclusion: Endovascular baroreflex amplification with the MobiusHD device was safe and effected positive changes in quality of life, exercise capacity, and LVEF, consistent with observed reductions in NT-proBNP levels.
No takes yet. Share an insight, caveat, or question.
Piayda et al. (2022) conducted an observational in Heart failure with reduced ejection fraction (n=29). Endovascular baroreflex amplification with the MobiusHD device was evaluated on Safety and changes in KCCQ OSS, 6MWD, NT-proBNP, and LVEF. Endovascular baroreflex amplification with the MobiusHD device in HFrEF patients improved mean KCCQ OSS by 17.4 points, 6MWD by 97.6 meters, and LVEF by 5.6% at 12 months.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: