Key result
Late Iodine Enhancement CT revealed that CRT non-responders more frequently had the LV lead positioned over an akinetic/dyskinetic area compared to responders.
Why the study?
Non-response to CRT stems from mechanical dyssynchrony, myocardial scar, and suboptimal LV lead location, prompting evaluation of LIE-CT with image subtraction to characterize non-responders.
Does Late Iodine Enhancement Computed Tomography (LIE-CT) identify anatomical and functional causes of non-response in patients who underwent cardiac resynchronization therapy?
Observational (n=29)
Does Late Iodine Enhancement Computed Tomography (LIE-CT) identify anatomical and functional causes of non-response in patients who underwent cardiac resynchronization therapy?
Answers are grounded in this paper and cite their sources.
Post-procedural LIE-CT identifies suboptimal LV lead placement over fibrotic or akinetic areas as a key driver of CRT non-response, offering potential guidance for lead repositioning.
INTRODUCTION: Causes of non-response to cardiac resynchronization therapy (CRT) include mechanical dyssynchrony, myocardial scar, and suboptimal left ventricular (LV) lead location. We aimed to assess the utility of Late Iodine Enhancement Computed Tomography (LIE-CT) with image subtraction in characterizing CRT non-response. METHODS: CRT response was defined as a decrease in LV end-systolic volume > 15% at 6 months. LIE-CT was performed after 6 months, and analyzed global and segmental dyssynchrony, myocardial scar, coronary venous anatomy, and position of LV lead relative to scar and segment of latest mechanical contraction. RESULTS: We evaluated 29 patients (age 71 ± 12 years; 72% men) including 18 (62%) responders. All metrics evaluating residual dyssynchrony such as wall motion index and wall thickness index were worse in non-responders. There was no difference in presence and extent of scar between responders and non-responders. However, in non-responders, the LV lead was more often over an akinetic/dyskinetic area (72% vs. 22%, p = .007), a fibrotic area (64% vs. 8%, p = .0007), an area with myocardial thickness < 6 mm (82% vs. 22%, p = .002), and less often concordant with the region of maximal wall thickness (9% vs. 72%, p = .001). Among the 11 non-responders, eight had at least another coronary venous branch visualized by CT, including three (27%) coursing over a potentially interesting myocardial area (free of scar, with normal wall motion, and with a myocardial thickness ≥6 mm). CONCLUSION: LIE-CT with image subtraction allows a comprehensive characterization of patients after CRT and may provide clues for management of non-responders.
No takes yet. Share an insight, caveat, or question.
Pezel et al. (2020) conducted an observational in Cardiac resynchronization therapy (CRT) non-response (n=29). Late Iodine Enhancement Computed Tomography (LIE-CT) vs. CRT responders was evaluated on LV lead over an akinetic/dyskinetic area (p=.007). Late Iodine Enhancement CT revealed that CRT non-responders more frequently had the LV lead positioned over an akinetic/dyskinetic area compared to responders.
Synapse has enriched 10 related papers. Consider them for comparative context: