Key result
Quadripolar LV leads are linked to ~23% fewer hospitalizations vs bipolar leads and are highly cost-effective.
Why the study?
Do quadripolar left ventricular leads improve cost-effectiveness compared to bipolar leads in patients receiving cardiac resynchronization defibrillator therapy?
Cohort (n=606)
Yes
Do quadripolar left ventricular leads improve cost-effectiveness compared to bipolar leads in patients receiving cardiac resynchronization defibrillator therapy?
Quadripolar LV leads for CRT-D are highly cost-effective compared to bipolar leads in the UK healthcare system, driven primarily by reduced heart failure hospitalizations and generator replacements.
Answers are grounded in this paper and cite their sources.
Quadripolar leads may reduce HF hospitalizations cost-effectively in CRT-D; leaves open need for randomized confirmation before practice change.
OBJECTIVES: The objective of this study was to evaluate the cost-effectiveness of quadripolar versus bipolar cardiac resynchronization defibrillator therapy systems. BACKGROUND: Quadripolar left ventricular (LV) leads for cardiac resynchronization therapy reduce phrenic nerve stimulation (PNS) and are associated with reduced mortality compared with bipolar leads. METHODS: A total of 606 patients received implants at 3 UK centers (319 Q, 287 B), between 2009 and 2014; mean follow-up was 879 days. Rehospitalization episodes were costed at National Health Service national tariff rates, and EQ-5D utility values were applied to heart failure admissions, acute coronary syndrome events, and mortality data, which were used to estimate quality-adjusted life-year differences over 5 years. RESULTS: Groups were matched with regard to age and sex. Patients with quadripolar implants had a lower rate of hospitalization than those with bipolar implants (42.6% vs. 55.4%; p = 0.002). This was primarily driven by fewer hospital readmissions for heart failure (51 [16%] vs. 75 [26.1%], respectively, for quadripolar vs. bipolar implants; p = 0.003) and generator replacements (9 [2.8%] vs. 19 [6.6%], respectively; p = 0.03). Hospitalization for suspected acute coronary syndrome, arrhythmia, device explantation, and lead revisions were similar. This lower health-care utilization cost translated into a cumulative 5-year cost saving for patients with quadripolar systems where the acquisition cost was <£932 (US $1,398) compared with bipolar systems. Probabilistic sensitivity analysis results mirrored the deterministic calculations. For the average additional price of £1,200 (US $1,800) over a bipolar system, the incremental cost-effective ratio was £3,692 per quality-adjusted life-year gained (US $5,538), far below the usual willingness-to-pay threshold of £20,000 (US $30,000). CONCLUSIONS: In a UK health-care 5-year time horizon, the additional purchase price of quadripolar cardiac resynchronization defibrillator therapy systems is largely offset by lower subsequent event costs up to 5 years after implantation, which makes this technology highly cost-effective compared with bipolar systems.
No takes yet. Share an insight, caveat, or question.
Behar et al. (2016) conducted a cohort in Heart failure requiring cardiac resynchronization defibrillator therapy (n=606). Quadripolar left ventricular leads vs. Bipolar left ventricular leads was evaluated on Rate of hospitalization (p=0.002). Quadripolar left ventricular leads for cardiac resynchronization therapy reduced hospitalization rates compared to bipolar leads and were highly cost-effective.