Key result
Newer TAVR devices linked to lower WBC and IL-6 rises versus original Sapien valves.
Why the study?
TAVR technology and delivery systems have rapidly evolved since the original SAPIEN valve, but changes in thromboinflammatory profiles across valve generations required evaluation.
Do newer generation TAVR valves reduce systemic inflammation compared to older generation valves in patients undergoing transfemoral TAVR?
Observational (n=145)
Do newer generation TAVR valves reduce systemic inflammation compared to older generation valves in patients undergoing transfemoral TAVR?
Newer generation TAVR devices and smaller delivery systems are associated with less systemic inflammation compared to earlier generations, as reflected by lower WBC and IL-6 levels.
Answers are grounded in this paper and cite their sources.
Newer TAVR valves associated with less inflammation should not change practice; hypothesis-generating and requires randomized confirmation.
The transcatheter aortic valve replacement (TAVR) procedure was developed to provide patients with severe aortic stenosis an alternative to the surgical aortic valve replacement. Since the approval of the original SAPIEN the technology has rapidly evolved. While several approaches can be used for valve deployment, as delivery systems have become smaller and more flexible, the transfemoral approach has become the dominant technique for valve deployment. One hundred and forty five patients undergoing TAVR receiving one of four valve types (Sapien, Sapien XT, Sapien3 or CoreValve) via the femoral artery were included in this study. Platelet count, white blood cells count (WBC), Interleukin-6 (IL-6), and Serum Amyloid A (SAA) were determined before and after TAVR. Platelet counts declined after the procedure regardless of the valve type and were dependent upon the baseline platelet count. Use of conscious sedation blunted the decline in platelet count. With the newer generation valves, the rise in WBC post-TAVR was lower than observed with the Sapien, in keeping with less systemic inflammation. Consistent with WBC, IL-6 levels were lower following deployment of the newer generation valves. Elevations in plasma SAA, which occur following myocardial injury, were not reduced with the newer valves. Evolution of the TAVR technology has occurred rapidly over the last 5 years. The newer devices and smaller delivery systems are associated with less systemic inflammation, as reflected in WBC and plasma IL-6 levels. However, the acute phase reactant SAA remains unchanged, possibly reflecting different triggers for SAA following TAVR.
No takes yet. Share an insight, caveat, or question.
Sexton et al. (2018) conducted an observational in Severe aortic stenosis (n=145). Newer generation transcatheter aortic valves (Sapien XT, Sapien3, CoreValve) vs. Original Sapien valve was evaluated on Changes in thromboinflammatory profiles (Platelet count, WBC, IL-6, SAA). Newer generation TAVR devices were associated with lower post-procedure rises in WBC and IL-6 compared to the original Sapien valve, indicating less systemic inflammation.
Synapse has enriched 10 related papers. Consider them for comparative context: